E53-C3D Omron, E53-C3D Datasheet - Page 3

no-image

E53-C3D

Manufacturer Part Number
E53-C3D
Description
0-20 CURRENT OUTPUT ES100&E5_J
Manufacturer
Omron
Datasheet

Specifications of E53-C3D

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E53C3D
Specifications
E5 J
Note: 1. If control period is less than 5 seconds, use solid state relay or voltage relay.
Note: 2. The E53-C3 Current Output Unit cannot be used if heater burnout alarm is used.
Part number
Supply voltage
Operating voltage
Power consumption
Temperature input type
Event
input
Control
output
Alarm
output
Heater
burnout
output
Indication
accuracy
Setting accuracy
Display Range
Control
mode
Memory protection
Other
functions
Indicators
Contact input
No-contact input
Type
Hysteresis
Update
time
Service
life
Number
Setting range
Type
Setting range
Minimum detectable
ON time
General
Exceptions
Type
Proportional band (P)
Reset time (I)
Rate time (D)
Control period
Sampling period
Input shift
Miscellaneous
Present value
Set value
Other functions
Relay
(see note 1)
Voltage
Current
Output
Display
Electrical
Mechanical
E5AJ
100 to 240 VAC, 50/60 Hz
85% to 110% of supply voltage range
Approx. 10 VA at 100 VAC to 14 VA at 240 VAC
Thermocouple types J, K, T, L, U, and N or platinum RTD (JPt 100/Pt100), selectable
ON: 1 k
ON: residual voltage: 3 V max.,
OFF: Leakage current 1 mA max.
SPST-NO, 5 A, 250 VAC using E53-R output unit
NPN, 40 mA at 12 VDC using E53-Q output unit
NPN, 20 mA at 24 VDC using E53-Q3 output unit
PNP, 20 mA at 24 VDC using E53-Q4 output unit
All offer short-circuit protection
4-20 mA, DC, 600
using E53-C output unit (see note 1)
0.1 to 999.9 C/F in units of 0.1 C/ F during ON/OFF control action
500 ms for pulse output
500 ms
100,000 operations minimum for E53-R and alarm
10 million moperations minimum for E53-R and alarm
Two SPST-NO relay,s 3 A, 250 VAC
Thermocouple types J, K, L, N: -1999 to 9,999 C/ F in units of 1 C/ F
Platinum RTD and thermocouple types T and U: -199.9 to 999.9 C/ F in units of 0.1 C/ F
SPST-NO relay, 1 A, 250 VAC
0.1 to 49.9 A in units of 0.1 A
0.0 setting disables the output
50.0 setting turns output ON continuously
200 ms; heater current is not measured when the control output is ON less than 200 ms
Accuracy of types K, N and T thermocouples is 2 C (3.6 F) from -100 C or below (-240 F or
below), 1 digit. Accuracy of type U thermocouple at any temperature is 2 C (3.6 F), 1 digit.
Set value coincides with the indicated value, since no relative error exists
between both values
-9999 to 9999 (limited by output type)
PID with automatic fuzzy self-tuning, PID, or ON/OFF
0.1 to 999.9 C/ F in units of 0.1 C/ F
0 to 3,999 seconds in 1-second units
0 to 3,999 seconds in 1-second units
Pulse output: 1 to 99 seconds in 1-second units
500 ms
Non-volatile memory
Offsets input value and display to accommodate a sensor input that deviates by a
known value.
Thermocouple range: -999 to 9999 C/ F
Platinum RTD range: -99.9 to 999.9 C/ F
Upper and lower set value limits, setting protection, Normal and Reverse output
15 mm (0.59 in)
red LED digits
10.5 mm (0.41 in)
green LED digits
LED indicators
0.5% of set point or 1 , whichever is greater, 1 digit max.
max., OFF: 100 k min.
max., resolution of 2,600
E5EJ
14 mm (0.55 in)
red LED digits
9.5 mm 0.37 in)
green LED digits
E5CJ
Approx 10 VA at 100 VAC to
12 VA at 240 VAC
SPST-NO, 3 A, 250 VAC
NPN, 20 mA at 12 VDC
4-20 mA, 600
of 2,600
Two, SPST-NO relays, 1 A, 250 VAC
12 mm (0.47 in)
red LED digits
8 mm (0.32 in)
green LED digits
max., resolution
E5 J
205