ME792A-MSP BLACK BOX, ME792A-MSP Datasheet

no-image

ME792A-MSP

Manufacturer Part Number
ME792A-MSP
Description
MICRODRIVER 9 RJ11 MALE W/ SUR
Manufacturer
BLACK BOX
Datasheet
Protocol: Asynchronous
Speed: 300 to 19.2 Kbps
Operation: 4-wire, Full-or Half-Duplex, point-to-point
Transmit Level: 0 dBm
Surge Protection: 600W power dissipation at 1 ms and
Control Signals: CTS (pin 8) turns ON immediately after
Interface: RS-232C/CCITT V.24
Connectors: (1) DB9 male/female (depending on model);
Power: No external power supply required; uses ultra-
DATA RATE (BPS)
MICRODRIVER
ME792A
19,200
9,600
4,800
2,400
1,200
response time of 1 picoseconds
the terminal raises RTS (pin 7). DSR (pin 6)
and DCD (pin 1) turn ON immediately after the
terminal raises DTR (pin 4).
(1) RJ-11 female
low power (+5VDC required, with current draw
of 3 to 5 ma at +10VDC) from EIA data and
control signals: Pins 3,4 and 7.
BLACK BOX
SPECIFICATIONS:
7.5 (12.1)
19 AWG
11.8 (19)
17 (27.4)
6.2 (10 )
8.7 (14)
DISTANCE IN MILES (km)
11.8 (19)
24 AWG
4.9 (7.9)
8 (12.9)
3.7 (6)
5.6 (9)
CONNECTOR
1 2 3 4 5 6
ME792A
DB9 M/F
RJ-11
1.2 (1.9)
4.9 (7.9)
26 AWG
8 (12.9)
2.5 (4)
3.7 (6)
Operating full-duplex over two unconditioned twisted-pair wires, the Microdriver supports data rate from 300 to 19,200 bps. The unit
draws all power from the RS-232 interface and requires no AC power or batteries.
connector. For added flexibility, the Microdriver is compatible with the ME771A-773A and the ME731A-733A.
transients. Providing 600 watts per wire of transient protection, this unit is recommended for environments prone to lightning storms,
static discharge, and other forms of EMR.
the twisted-pair and RS-232 interfaces, and how to operate it.
handshaking signals. There are two essential requirements for installing the Microdriver.
table below.
should be constructed for an environment where both Microdrivers use a 6-wire RJ-11 connector.
The DB9 Microdriver lets two asynchronous RS-232 devices with DB9 connectors communicate at distances up to 17 miles (27 km).
It's tiny size lets the Microdriver fit in very tight installation spaces. And you can make twisted-pair connections using the RJ-11
These units use the latest in bi-directional, clamping transient suppressors to guard itself and connected equipment from data line
The Microdriver is easy to install and requires no pre-configuration. This section tells you how to properly connect the Microdriver to
The DB9 Microdriver operates full-duplex in point-to-point environments. It passes both data and X-ON/X-OFF (software)
The RJ-11 on the Microdriver is pre-wired for a standard AT&T wiring environment. To be sure you have the right wiring, use the
When you connect two DB9 Microdrivers, you must use a cross-over cable. The diagram below shows how a cross-over cable
1. You must use Microdrivers in pairs. You must have one unit at each end of a two twisted-pair interface.
2. You must use two twisted pairs of metalllic wire. These pairs must be unconditioned dry, metallic wire, between 19 and 26
Connection to ground is optional. If there is a shield around the telephone cable, it may be
connected to "G" (GND) on the RJ-11 connector. Connect the shield only at the computer end to
avoid ground loops. A ground wire is not necessary for proper operation of these units.
AWG (lower-number gauges allow greater distances).
that run through signal equalization equipment.
SURGE PROTECTION
ME792A-M/F WITH
TABLE
RJ-11 PIN #
1
2
3
4
5
6
INSTALLATION:
DESCRIPTION:
DIAGRAM
Do not
GND
Ground is Optional)
SIGNAL
RCV+
XMT+
RCV-
XMT-
(Connection to
GND
use standard dial-up telephone circuits or leased circuits