GU280X16G-7806A Noritake Company Inc, GU280X16G-7806A Datasheet
GU280X16G-7806A
Specifications of GU280X16G-7806A
Related parts for GU280X16G-7806A
GU280X16G-7806A Summary of contents
Page 1
... Chicago USA: +1-847-439-9020 8 Munchen (D): +49 (0)89-3214-290 O 9600 Itron UK: +44 (0)1493 601144 Rest Europe: +49 (0)61-0520-9220 O 19200 www.noritake-itron.com O 38400 Self Test Mode Subject to change without notice. IUK Doc Ref: 10405 Iss:5 09Oct07 GU280x16G-7806A Async SPI SCK RXD /SS LINK1 SIN 0V 0V LINK2 SOUT TXD ...
Page 2
... Additional Serial Data Commands Set the RS line low for the following byte only. Used in serial communications only. Read data at current cursor position. This command is used with serial communications only. Read current cursor position. This command is used with serial communications only. GU280x16G-7806A GU280x16G-7806A ...
Page 3
... VDD GND >100ns >100ns GU280x16G-7806A X1, Y1 DATA DIRECTION MSB Horizontal Data & Vertical Movement Movement >30ns >25ns >20ns >30ns <25ns >30ns >200ns <65ns >50ns VALID >25ns >20ns >100ns LOWER NIBBLE <120ns tBUSY GU280x16G-7806A DATA DIRECTION tBUSY ...
Page 4
... TTL Synchronous serial communication. DISPLAY TEXT ‘NORITAKE ITRON’ ‘VFD MODULES’ GU280x16G-7806A >250ns >50ns >250ns LOWER NIBBLE Valid STOP START <200us >250ns >250ns <20us MSB LSB MSB LSB >250ns Displaying text using serial communications. GU280x16G-7806A <20us tBUSY STOP tBUSY >250ns ...
Page 5
... Command Structure and Values Copyright 2007 Noritake Co Limited, Japan DISPLAY TEXT ‘NORITAKE ITRON’ ‘VFD MODULES’ DISPLAY TEXT ‘280x16’ GU280x16G-7806A 0,0 0,7 6,7 Cursor Positioning, example of writing 2 characters from cursor position 0,7. Displaying text using the 5x7 font. Displaying text in the large 10x14 font. GU280x16G-7806A ...
Page 6
... Displaying graphic images in vertical and horizontal format. Display options with simple graphic text write. Boxes created using the ‘Set Area Outline’ command. Drop Shadows created with the ‘Fill Area’ command. Option ‘Run’ selected with the ‘Invert Area’ command. GU280x16G-7806A - 1CH - 5CH - 48H - 3EH ...
Page 7
... TXD OUT MISO OUT MOSI OUT RXD OUT F7H TXD IN MISO IN MOSI IN RXD IN F4H + SETUP TXD OUT HNDSHK DEF H/L CLK EDGE SPEED1 F6H + DATA F8H + SIZE + DATA F5H PEND TXC RXC F7H GU280x16G-7806A D0 SCK I/O D0 SCK OUT D0 SCK IN D0 SPEED0 D0 - ...
Page 8
... The TXC bit is cleared after status read. SERIAL READ F7H The currently buffered data byte can be read with RS high. The host should first check the RXC bit using the PORT STATUS command. After reading the data byte, the RXC bit is cleared. GU280x16G-7806A PARITY0 BAUD1 ...