10250T201NC1N EATON CUTLER HAMMER, 10250T201NC1N Datasheet - Page 280
10250T201NC1N
Manufacturer Part Number
10250T201NC1N
Description
INDICATOR, INCAND LAMP, BAYONET
Manufacturer
EATON CUTLER HAMMER
Datasheet
1.10250T102.pdf
(320 pages)
Specifications of 10250T201NC1N
Base Type
Bayonet
Supply Voltage
120V
Current Rating
6A
Contact Current Max
6A
Illumination
Illuminated
Switch Features
Resistor
Actuator Style
Pushbutton
Color
Red
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
- Current page: 280 of 320
- Download datasheet (7Mb)
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47.9
30.5 mm Class I Division 2 Hazardous Locations—10250T/E34
Product Description
All the Industry-Proven
Quality of Eaton’s 10250T and
E34 Series of Logic Devices,
plus Class I Division 2
Certification
The 10250T1H consists of a
normally open-normally
closed factory sealed contact
block that is UL Listed for use
in Class I, Division 2, Groups
B, C and D (NEC 500–503)—
Class I, Zone 2, IIB + H2 (NEC
505) hazardous locations and
is rated for both NEMA A600
and NEMA Q300. 10250T
and E34 illuminated
components have also been
UL Listed for use in Class I,
Division 2, Groups B, C and D
(NEC 500–503)—Class I,
Zone 2, IIB + H2 (NEC 505).
This, combined with the
industry-proven Eaton
10250T 30.5 mm pushbutton
line, offers a complete
solution to Division 2
hazardous location
requirements.
280
Control Products Catalog CA08102001E—August 2010 www.eaton.com
Pushbuttons and Indicating Lights
30.5 mm Class I Division 2 Hazardous Locations—10250T/E34
Single composite catalog
numbers for complete
assembled stations and
operators for use in Division 2
hazardous locations are
featured throughout this
section.
Features
●
●
●
●
●
●
●
Factory sealed contact
blocks
Heavy-duty zinc die cast
construction
NEMA rated 1, 2, 3, 3R, 4,
4X, 12, 13
Front-of-panel drainage
holes
Grounding nibs on the
operator casing
Solid thermosetting
cathodic epoxy coating on
E34
Corrosion resistance in
E34
Contents
Description
30.5 mm Class I Division 2 Hazardous Locations—
Benefits
●
●
●
●
●
10250T/E34
Pushbutton for hazardous
locations
Drainage holes prevent
buildup of liquid inside the
operator which can prevent
operation in freezing
environments
Grounding nibs bite
through paint and other
coatings to provide secure
ground
Suitable for corrosive
environments (E34 only)
Earth terminal provides
additional grounding point
and allows for daisy chain
grounding (E34 line)
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . 282
Product Selection
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
Technical Data and Specifications . . . . . . . . . . . . . . . . . 316
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Momentary Pushbutton Units . . . . . . . . . . . . . . . . . . 283
Non-Illuminated Pushbutton Units . . . . . . . . . . . . . . 287
Illuminated Pushbutton Units . . . . . . . . . . . . . . . . . . 289
Guarded Illuminated Pushbutton Units . . . . . . . . . . . 290
Indicating Light Units . . . . . . . . . . . . . . . . . . . . . . . . 291
Illuminated Pushbuttons and Indicating Lights . . . . . 292
Push-Pull Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Illuminated Push-Pull Units . . . . . . . . . . . . . . . . . . . . 296
Push-Pull Operators . . . . . . . . . . . . . . . . . . . . . . . . . 299
Selector Switch Units . . . . . . . . . . . . . . . . . . . . . . . . 303
Selector Switch Selection . . . . . . . . . . . . . . . . . . . . . 305
Selector Switch Operators . . . . . . . . . . . . . . . . . . . . 308
Illuminated Selector Switch Operators . . . . . . . . . . . 311
Standards and
Certifications
●
●
●
●
Ingress Protection
●
●
UL 508—File No. E131568
UL 1604—File No. E10323
CSA Certified C22.2
No.14—File No. LR 68551
CSA Certified C22.2 No.
213-M1987—File No. LR
20713
Standard indicating lights
●
●
All other operators
●
●
UL (NEMA) Type 3, 3R,
3S, 4, 4X, 12, 13
IEC IP65
UL (NEMA) Type 3, 3R,
4, 4X, 12, 13
IEC IP65
Page
Related parts for 10250T201NC1N
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
CONTACT BLOCK, 2NO, 6A, SCREW
Manufacturer:
EATON CUTLER HAMMER
Datasheet:
Part Number:
Description:
RECEPTACLE, MDR, R/A, 50WAY
Manufacturer:
3M
Datasheet:
Part Number:
Description:
RECEPTACLE, MDR, STRAIGHT, 50WAY
Manufacturer:
3M
Datasheet:
Part Number:
Description:
CONN MDR RECPT 50POS VERT T/H
Manufacturer:
3M
Datasheet:
Part Number:
Description:
CONN MDR RECEPT 50POS R/A SMD
Manufacturer:
3M
Datasheet:
Part Number:
Description:
CONN MDR RCPT 50POS R/A 4-40
Manufacturer:
3M
Datasheet:
Part Number:
Description:
CONN MDR RCPT 50POS R/A SMD 20AU
Manufacturer:
3M
Datasheet:
Part Number:
Description:
CONN MDR RECPT 50POS IDC GOLD
Manufacturer:
3M
Datasheet:
Part Number:
Description:
Handle Tie Bar For (2) - 1 Pole Type BR Breakers
Manufacturer:
EATON CUTLER HAMMER
Part Number:
Description:
Type CL Breaker 25A/1Pole 120/240V 10K-Classified 1" Ckt Bkr
Manufacturer:
EATON CUTLER HAMMER