Trouble Shooting & User Hints
Note: All passive infra red detectors are more sensitive in cold and dry weather than warm and wet weather.
Cleaning
To avoid dust build-up and ensure proper functioning of
the floodlight, please wipe the sensor lens lightly with a
damp cloth every 3 months.
Disconnect the power and clean the exterior only of this
fitting with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners.
Lamp Replacement
1.
2.
Installation Instructions & Care
Problem
Light does not switch on when
there is movement in the
detection area
Lamp switches on for no
apparent reason (false trigger)
Light remains on
Light switches on during daylight
hours
When setting lux controls in
daylight the detection distance
becomes shorter
Switch off the electricity at the mains.
Using a cross-headed screwdriver, loosen the screws
and lift off the diffuser.
Possible Cause
1. No mains voltage
2. Bulb - faulty/missing
3. Light nearby is too bright
4. Controls set incorrectly
5. Sensor postioned in wrong direction
1. Heat from lamp body activating sensor
2. Heat sources i.e; air-con, vents, heater flues,
3. Animals or birds e.g. possums or domestic
4. Interference from on/off switching of
5. Reflection from swimming pool or reflective
1. Continuously false triggered
2. Time to set too long
1. LUX control knob is set to daylight position
1. Interference by sunlight
bbq’s, outside light, moving cars can activate
sensor
animals
surface
electric fans, lights on the same circuit as
your security floodlight. (This problem does
not always occur but a faulty switch or noisy
fluorescent light may cause the security
floodlight to switch on
5
3.
4.
5.
6.
Replacement Lamp Type
Wattage: 24W
Type: 24W ES Helical CFLi
This fitting is designed for low energy compact
fluorescent lamps, do not use incandescent or halogen
lamps.
Remove the lamp. Pull directly out of lampholder,
do not twist.
Insert new lamp.
Replace the diffuser and secure in position making
sure that the gasket is correctly positioned and
compressed.
Restore the power and switch on.
Suggested Solutions
• Check all connections, fuses and switches
• Check. Replace
• Redirect sensor or relocate the unit
• Readjust sensor angle or control knob
• Redirect sensor and/or adjust
• Adjust PIR sensor or floodlight to allow a
• Adjust direction of sensor head away from
• Redirecting sensor may help
• Should the false triggering become,
troublesome, consider:
(a) Replacing a faulty switch.
(b) Replacing noisy fluorescent tubes/starters
(c) Connecting the floodlight to a separate
• Redirecting sensor head may help
• Reduce time
• Turn the LUX control knob to desired light
• Re-test at night
minimum gap 40mm between floodlight
body and sensor head
these sources
level setting
circuit (in most cases where one or more
of the above suggestions have been
carried out, false triggering has been
reduced)
• Relocate the fitting