CP41S CROMPTON LIGHTING, CP41S Datasheet - Page 3

BATTEN, SINGLE, 36W, 4FT, S/S

CP41S

Manufacturer Part Number
CP41S
Description
BATTEN, SINGLE, 36W, 4FT, S/S
Manufacturer
CROMPTON LIGHTING
Datasheet

Specifications of CP41S

Supply Voltage
230V
Base Type
G13
Power Rating
36W
Length
1238mm
Colour Temperature Typ
3500K
Colour
White
External Depth
92mm
External Length / Height
1238mm
External Width
58mm
Fluorescent
RoHS Compliant
Lamp Base Type
G13
Rohs Compliant
Yes
Depth
92mm
Bulb Diameter
26mm
138
Crompack 5
Lamp and Control Gear Options
• Triphosphor 18W, 36W, 58W and 70W,
• 100W T12 fluorescent, 3500°K - G13 cap
• 14W, 28W 35W (HE), 24W, 49W, 54W and
• High frequency or switch start control gear as standard
• Dimming options including DSI and DALI
Materials
• Body - Rigid steel channel, powder coated in RAL9016 finish
• End cap - Injection moulded, colour matched to body
Installation Notes
• Suitable for direct fix, trunking, conduit or chain suspension
• BESA entries (except 14/18/24W). Central and at 600mm fixing
• End cable entry only on T5 14/24W versions
• Keyhole slots for screw fixing at 600mm centres
• Can be continuously mounted, aligned using interlocking end
• 20mm knockout in end caps
• Angled 2 x 2.5mm
• Intellect versions require simple set-up. See page 507
• All versions are high power factor corrected (except 18W)
• Supplied complete with lamps or less lamp as required
Dimensions
D
Lamp Rating
T8/12 lamps
1x18W
1x36W
1x58W
1x70W
1x100W
2x18W
2x36W
2x58W
2x70W
2x100W
T5 lamps
1x14/24W
1x28/54W
1x35/49/80W
2x14/24W
2x28/54W
2x35/49/80W
T8 fluorescent 4000°K - G13 cap
80W- (HO) T5 fluorescent, 4000°K - G5 cap
centres (100W - 1200mm)
(14/24W - 435mm,18W - 525mm, 100W - 1200mm)
caps
W
L
L (mm)
1238
1538
1802
2413
1238
1538
1802
2413
1238
1538
1238
1538
627
627
627
627
2
terminal block
Surface and Suspended
W (mm)
58
58
58
58
58
89
89
89
89
89
58
58
58
58
58
58
D (mm)
92
92
92
92
92
92
92
92
92
92
80
80
80
80
80
80
Cable Entry
605mm
525mm
T12
T8
T5
120°
120°
90°
60°
90°
60°
T8 versions
Options
• Intellect light and energy management options (refer to Controls
• Fully integral emergency conversion (18W is fully remote,
• Intellem self-test emergency versions available
• Suitable for use on defined escape routes, batten only and all
Specification
To specify state: BSI Kitemarked and
manufactured from rigid rolled steel channel profile, with high quality,
durable post coat powder paint finish and secure, screw fixed cover
plate, as Crompton Crompack 5 range, part no. ________
Photometric Data
Cat. No.
LOR:
ULOR:
DLOR:
SHR nom: 1.75
SHR max: 1.87
Cat. No.
LOR:
ULOR:
DLOR:
SHR nom: 1.75
SHR max: 1.97
30°
30°
Guide on page 505)
28/54W have remote batteries), 3 hour duration
reflectors or wire guards
CP42ZT
0.96
0.31
0.65
CP235Z
0.95
0.25
0.70
cd/1000lm
cd/1000lm
120
120
160
80
80
30°
30°
120°
90°
60°
120°
90°
60°
Utilisation factors / TM5
See page 560 for Design Guide
Utilisation factors / TM5
See page 560 for Design Guide
70
50
30
70
50
30
C
C
Reflectances
0
Reflectances
0
BZ-class
BZ-class
W
50
30
10
50
30
10
50
30
10
W
50
30
10
50
30
10
50
30
10
0
0
20
20
20
20
20
20
F
0
F
0
0.75
0.75
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1
-
-
-
-
-
-
-
-
-
-
-
1.0
1.0
52
45
39
47
41
36
42
37
33
27
53
46
40
49
42
38
44
39
35
30
6
6
marked batten luminaire,
1.25
1.25
59
51
46
52
46
42
46
42
38
31
60
52
47
54
48
44
49
44
40
34
6
6
1.5
1.5
63
56
51
56
51
46
50
45
42
34
65
58
52
59
53
48
53
48
45
38
Room Index
Room Index
6
6
2.0
2.0
70
64
58
62
57
53
55
51
47
39
71
65
60
65
59
55
58
54
51
43
6
6
2.5
2.5
75
69
64
66
61
57
58
55
52
42
76
70
65
69
64
60
62
58
55
47
6
6
3.0
3.0
78
73
68
69
65
61
61
58
55
45
79
74
69
72
67
64
65
61
58
50
6
6
4.0
4.0
83
78
74
73
69
66
64
62
59
48
84
79
75
76
72
69
68
65
63
53
6
6
5.0
5.0
86
81
78
76
73
70
67
64
62
51
87
83
79
78
75
72
70
68
66
56
6
6

Related parts for CP41S