ACPL-331J-500E Avago Technologies US Inc., ACPL-331J-500E Datasheet
ACPL-331J-500E
Specifications of ACPL-331J-500E
Available stocks
Related parts for ACPL-331J-500E
ACPL-331J-500E Summary of contents
Page 1
... The voltage and current supplied by these optocouplers make them ideally suited for directly driving IGBTs with ratings up to 1200 V and 100 A. For IGBTs with higher ratings, the ACPL-331J can be used to drive a discrete power stage which drives the IGBT gate. The ACPL-331J has an insulation voltage of V ...
Page 2
... To order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry. Example 1: ACPL-331J-500E to order product of SO-16 Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-2 Safety Approval in RoHS compliant. Example 2: ACPL-331J-000E to order product of SO-16 Surface Mount package in tube packaging with IEC/EN/DIN EN 60747-5- 2 Safety Approval and RoHS compliant ...
Page 3
... Dimensions in inches (millimeters) Notes: Initial and continued variation in the color of the ACPL- 331J’s white mold compound is normal and does note affect device performance or reliability. Floating Lead Protrusion is 0.25 mm (10 mils) max. Recommended Pb-Free IR Profile Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision) ...
Page 4
... Regulatory Information The ACPL-331J is approved by the following organizations: IEC/EN/DIN EN 60747-5-2 Approval under: IEC 60747-5-5 :1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01 Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 V rms for rated mains voltage ≤ ...
Page 5
... Table 4. Recommended Operating Conditions Parameter Operating Temperature Total Output Supply Voltage Negative Output Supply Voltage Positive Output Supply Voltage Input Current (ON) Input Voltage (OFF) 5 ACPL-331J Units Conditions 8.3 Mm Measured from input terminals to output terminals, shortest distance through air. 8.3 Mm Measured from input terminals to output terminals, shortest distance path along body ...
Page 6
Table 5. Electrical Specifications (DC) Unless otherwise noted, all typical values at T all Minimum/Maximum specifications are at Recommended Operating Conditions. Parameter Symbol FAULT Logic Low V FAULTL Output Voltage FAULT Logic High I FAULTH Output Current High Level I ...
Page 7
Table 6. Switching Specifications (AC) Unless otherwise noted, all typical values at T all Minimum/Maximum specifications are at Recommended Operating Conditions. Parameter Symbol Propagation Delay Time t PLH to High Output Level Propagation Delay Time t PHL to Low Output ...
Page 8
... O IGBT protection. UVLO is needed to ensure DESAT is functional. Once V until V is decreased below V . Thus, the DESAT detection and UVLO features of the ACPL-331J work in conjunction to ensure constant CC2 UVLO- IGBT protection. 10. See the DESAT fault detection blanking time section in the applications notes at the end of this data sheet for further details. ...
Page 9
Figure 1. Timing Curve 0 ____ -0.5 -1 -1.5 -2 -2.5 -40 - TEMPERATURE - A Figure 2. V vs. temperature 0.0 0.2 0.4 0 OUTPUT ...
Page 10
I _____ _ ___ I 3.00 2.75 2.50 2.25 2.00 -40 - TEMPERATURE - A Figure 6. I vs. temperature CC2 -0.20 -0.25 -0.30 -0.35 -40 - ...
Page 11
LOAD RESISTANCE - ohm Figure 12. Propagation delay vs. load resistance 250 200 150 100 -40 - TEMPERATURE - A Figure 14. DESAT sense to 90% V ...
Page 12
CC1 CC1 3 3 FAULT FAULT CATHODE CATHODE 6 6 ANODE ANODE 7 7 ANODE ANODE 10mA 10mA 8 8 CATHODE CATHODE ...
Page 13
CC1 CC1 LED LED 3 3 FAULT FAULT DESAT DESAT ...
Page 14
CC1 CC1 3 3 FAULT FAULT CATHODE CATHODE 6 6 ANODE ANODE 7 7 ANODE ANODE 10mA 10mA 10mA 8 8 CATHODE ...
Page 15
CC1 CC1 2.1kΩ FAULT FAULT 3 3 FAULT FAULT CATHODE CATHODE 6 6 ANODE ...
Page 16
CC1 CC1 2.1kΩ FAULT 15pF 0.1μF μ CATHODE 6 6 ANODE 430Ω ANODE 8 8 CATHODE ...
Page 17
... S SHIELD Figure 32. Block Diagram of ACPL-331J Recommended Application Circuit The ACPL-331J has an LED input gate control, and an open collector fault output suitable for wired ‘OR’ ap- plications. The recommended application circuit shown in Figure 33 illustrates a typical gate drive implementa- tion using the ACPL-331J. The following describes about driving IGBT ...
Page 18
... B &$7+2'( Figure 33. Recommended application circuit (Single Supply) with desaturation detection and active Miller Clamp Description of Operation Normal Operation During normal operation the ACPL-331J is con- OUT trolled by input LED current I (pins and 8), with F the IGBT collector-to-emitter voltage being monitored through D ...
Page 19
... This nominal blanking time represents the longest time it will take for the ACPL-331J to respond to a DESAT fault condition. If the IGBT is turned on while the collector and emitter are shorted to the supply rails (switching into a short), the soft shut-down sequence will begin after approximately 3 μ ...
Page 20
... Under Voltage Lockout The ACPL-331J Under Voltage Lockout (UVLO) feature is designed to prevent the application of insufficient gate voltage to the IGBT by forcing the ACPL-331J output low during power-up. IGBTs typically require gate voltages achieve their rated V At gate voltages below 13 V typically, the V increases dramatically, especially at higher currents ...
Page 21
Capacitor on FAULT Pin for High CMR Rapid common mode transients can affect the fault pin voltage while the fault output is in the high state. A 330 pF capacitor should be connected between the fault pin and ground to ...
Page 22
... Thermal Model The ACPL-331J is designed to dissipate the majority of the heat through pins & 8 for the input IC and pins 9 & 12 for the output IC. (There are two V output side, pins 9 and 12, for this purpose.) Heat flow through other pins or through the package directly into ambient are considered negligible and not modeled here ...