Specifications of ACSL-6400-00T

Rohs Compliant
NO
Voltage - Isolation
2500Vrms
Number Of Channels
4, Unidirectional
Current - Output / Channel
50mA
Data Rate
15MBd
Propagation Delay High - Low @ If
44ns @ 8mA
Current - Dc Forward (if)
15mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount
Package / Case
16-SOIC (0.154", 3.90mm Width)
Number Of Elements
4
Baud Rate
15Mbps
Forward Voltage
1.8V
Forward Current
15mA
Output Current
50mA
Isolation Voltage
2500Vrms
Package Type
SOIC N
Operating Temp Range
-40C to 100C
Power Dissipation
40mW
Propagation Delay Time
100ns
Pin Count
16
Mounting
Surface Mount
Reverse Breakdown Voltage
5V
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACSL-6400-00TE
Manufacturer:
AVAGO
Quantity:
1 026
Part Number:
ACSL-6400-00TE
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Regulatory Information
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(Clearance)
Minimum Externa l Tracking
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option X6X Only)
Description
Installation Classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b *
Input to Output Test Voltage, Method a *
Highest Allowable Overvoltage *
(Transient Overvoltage, t
Safety Limiting Values (Maximum values allowed in the event of a failure)
Insulation Resistance at T
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in applica-
tion.
8
V
Test with t
V
T
for rated mains voltage ≤150V rms
for rated mains voltage ≤300V rms
Case Temperature
Input Current
Output Power
m
IORM
IORM
700
600
500
400
300
200
100
= 60 sec, Partial Discharge < 5 pC
0
x 1.875 = V
x 1.5 = V
0
25
m
= 1 sec, Partial Discharge < 5 pC
PR,
50
Ts-Case Temperature,°C
Type and Sample Test,
PR
, 100% Production
75 100 125 150 175
ini
S
, V
= 10 sec)
IO
= 500V
Is (mA)
Ps (mW)
Symbol
L(I01)
L(I02)
CTI
200
Value
4.9
4.5
0.08
175
IIIa
Symbol
V
V
V
V
T
I
P
R
S,INPUT
S
IORM
PR
PR
IOTM
S,OUTPUT
IO
Units
mm
mm
mm
Volts
Conditions
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path through body
Insulation thickness between emitter and
detector; also known as distance through
insulation
DIN IEC 112/VDE0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
ACSL-6XX0-X6X
I-IV
I-III
55/100/21
2
560
1050
840
4000
175
150
600
10
9
Units
V
V
V
V
°C
mA
mW
Ω
peak
peak
peak
peak

Related parts for ACSL-6400-00T