HCPL-4502-320E Avago Technologies US Inc., HCPL-4502-320E Datasheet - Page 7

no-image

HCPL-4502-320E

Manufacturer Part Number
HCPL-4502-320E
Description
NPN-Output Dc-Input Optocoupler,1-CHANNEL,3.75kV ISOLATION,SO
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-4502-320E

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
8mA
Data Rate
1Mbps
Propagation Delay High - Low @ If
200ns @ 16mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount, Gull Wing
Package / Case
8-SMD Gull Wing
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Recommended Pb-Free IR Profile
Regulatory Information
The devices contained in this data sheet have been approved by the following organizations:
UL
Recognized under UL 1577, Component Recognition
Program, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5,
File CA 88324.
Insulation and Safety Related Specifications
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
7
Parameter
Minimum External
Air Gap (External
Clearance)
Minimum External
Tracking (External
Creepage)
Minimum Internal
Plastic Gap
(Internal Clearance)
Minimum Internal
Tracking (Internal
Creepage)
Tracking Resistance
(Comparative
Tracking Index)
Isolation Group
T
T
smax
smin
25
Tp
TL
217°C
150 - 200°C
t 25°C to PEAK
60 to 180 SEC.
PREHEAT
3°C/SEC. MAX.
ts
RAMP-UP
L(101)
L(102)
CTI
* 260 +0/-5°C
Symbol
TIME
8-Pin DIP
Value
7.1
7.4
0.08
NA
200
IIIa
(300 Mil)
t
tp
L
TIME WITHIN 5°C of ACTUAL
PEAK TEMPERATURE
15 SEC.
60 to 150 SEC.
RAMP-DOWN
6°C/SEC. MAX.
SO-8
Value
4.9
4.8
0.08
NA
200
IIIa
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
(HCNW and Option 060 only)
Widebody
(400 Mil)
Value
9.6
10.0
1.0
4.0
200
IIIa
Notes:
The time from 25°C to peak
Temperature = 8 minutes max.
T
Non-halide flux should be used.
* Recommended peak temperature for
smax
Widebody 400mils package is 245°C
Units
mm
mm
mm
mm
Volts
= 200°C, t
Measured from input terminals
to output terminals, shortest
distance through air.
Measured from input terminals
to output terminals, shortest
distance path along body.
Through insulation distance,
conductor to conductor, usually
the direct distance between the
photoemitter and photodetector
inside the optocoupler cavity.
Measured from input terminals
to output terminals, along
internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group
(DIN VDE 0110, 1/89, Table 1)
smin
= 150°C
Conditions

Related parts for HCPL-4502-320E