102009-1FR1 RF Solutions, 102009-1FR1 Datasheet - Page 3

REMOTE CONTROL SYSTEM, FM, 1CH

102009-1FR1

Manufacturer Part Number
102009-1FR1
Description
REMOTE CONTROL SYSTEM, FM, 1CH
Manufacturer
RF Solutions
Datasheet

Specifications of 102009-1FR1

Svhc
No SVHC (15-Dec-2010)
Approval Bodies
ETSI300/220
Frequency
433.92MHz
Operating Temperature Max
60°C
Operating Temperature Min
0°C
Range
200m
Supply Voltage
230V
DS009-1
Learning a new Transmitter Encoder
To enter and activate the learn mode the following sequence must be performed.
1. Power the receiver unit up and wait 10secs for the unit to enter ‘normal operation’ mode.
2. Switch the receiver unit OFF and then ON again in ~1sec intervals four times finally leaving the unit
3. After 5secs until a ‘beep’ sound is heard.
4. The unit is now in ‘learn’ Mode.
5. Briefly press a button on the transmitter, the receiver unit will ‘beep’ twice.
6. Briefly Press the transmitter button again, he receiver unit will ‘beep’ three times.
7. Wait 10sec for the unit to return to ‘normal operation’ mode.
8. The transmitter is now ‘learnt’ to the receiver unit and will operate the output relays.
Erasing Transmitter Encoders form Memory
To enter and activate the erase mode the following sequence must be performed.
1. Power the receiver unit up and wait 10secs for the unit to enter ‘normal operation’ mode.
2. Switch the unit off and then on again in ~1sec intervals six times finally leaving the unit powered up.
3. Wait 5secs until a ‘ticking’ sound is heard for a period of 10secs by the operation and release of one of the
4. Wait 10secs for the receiver unit to return to ‘normal’ mode
5. The unit has now erased all encoder data.
relays.