DSO9104A AGILENT TECHNOLOGIES, DSO9104A Datasheet - Page 21

OSCILLOSCOPE, 1GHZ, 4 CHANNEL, 20GSPS

DSO9104A

Manufacturer Part Number
DSO9104A
Description
OSCILLOSCOPE, 1GHZ, 4 CHANNEL, 20GSPS
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of DSO9104A

Scope Type
Digital
Scope Channels
4 Analog
Bandwidth
1GHz
Meter Display Type
XGA TFT-LCD Color
Sampling Rate
20GSPS
Input Impedance
1Mohm
Rise Time
253ps
Input Voltage
150Vrms
Lead Free Status / RoHS Status
na
Infi niium 9000 Series performance characteristics
Trigger: digital channels MSO Models
Threshold range (user defined)
Threshold accuracy
Measurements and math
Waveform measurements
Eye-diagram measurements
Measurement modes
FFT
2 Requires MATLAB software.
Voltage (scope channels)
Time (digital channels)
Time (scope channels)
Mixed (scope channels only)
Frequency domain
Level qualification
Statistics
Histograms (scope channels)
Marker modes
Waveform math
Automatic measurements
Multipurpose
Drag-and-drop
measurement toolbar
Frequency range
Frequency resolution
Window modes
Source
Orientation
Measurements
Number of functions
Operators
±8.0 V in 100-mV increments
±(100 mV + 3% of threshold setting)
(can be made on either min or zoom window with up to 10 simultaneous measurements
with statistics)
Peak-to-peak, minimum, maximum, average, RMS, amplitude, base, top, overshoot, V overshoot,
preshoot, V preshoot, upper, middle, lower, crossing point voltage , pulse top, pulse base, pulse
amplitude
Period, frequency, positive width, negative width, duty cycle, delta time
Rise time, fall time, period, frequency, positive width, negative width, duty cycle, Tmin, Tmax, Tvolt,
channel-to-channel delta time, channel-to-channel phase , count pulses , burst width, burst period,
burst interval, setup time, hold time
Area, slew rate
FFT frequency, FFT magnitude, FFT delta frequency, FFT delta magnitude
Any channels that are not involved in a measurement can be used to level-qualify all timing
measurements
Eye height, eye width, eye jitter, crossing percentage, Q factor, and duty-cycle distortion
Displays the mean, standard deviation, minimum, maximum range, and number of measurement values
for the displayed automatic measurements
Waveform or measurement (histogram on measurement requires EZJIT or EZJIT+ option)
Vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes,
regions are defined using waveform markers
Mean, standard deviation, mean ± 1, 2, and 3 sigma, median, mode, peak-to-peak, min, max, total
hits, peak (area of most hits), X scale hits, and X offset hits
Manual markers, track waveform data, track measurements
Four
Absolute value, add, average, Butterworth
phase, FIR
magnify, max, min, multiply, RT Eye
Chartstate (MSO models), charttiming (MSO models)
Measure menu access to all measurements, ten measurements can be displayed simultaneously
Front-panel button activates up to ten pre-selected or ten user-defined automatic measurements
Measurement toolbar with common measurement icons that can be dragged and dropped onto the
displayed waveforms
DC to 10 GHz (at 20 GSa/s) or 5 GHz (at 10 GSa/s)
Resolution = sample rate/memory depth
Hanning, flattop, rectangular , Blackman Harris, Force
11
, high pass filter, integrate, invert, LFE
2
, smoothing, SqrtSumOfSquare
2
, common mode, differentiate, divide, FFT magnitude, FFT
2
, low pass filter (4th-order Bessel Thompson filter),
2
, square, square root, subtract, versus
21