FLUKE-125/003 Fluke, FLUKE-125/003 Datasheet - Page 3

SCOPE METER, 40MHZ, 2 CHANNEL, 25MSPS

FLUKE-125/003

Manufacturer Part Number
FLUKE-125/003
Description
SCOPE METER, 40MHZ, 2 CHANNEL, 25MSPS
Manufacturer
Fluke
Type
Digitalr

Specifications of FLUKE-125/003

Scope Type
Digital Hand Held
Scope Channels
2 Scope
Bandwidth
40MHz
Meter Display Type
LCD Monochrome
Sampling Rate
25MSPS
Input Impedance
1Mohm
Rise Time
8.75ns
Input Voltage
1kV
Brand/series
ScopeMeter®/120 Series
Configuration
Handheld
Display Type
Monochrome LCD
Memory
512 pts
Number Of Channels
2
Sample Rate
0.025 GS/s
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Automatic Scope Measurements
Vdc, Vac rms, Vac+dc, Vpeak max, Vpeak min, Vpeak to
peak, Aac, Adc, Aac+dc, frequency (Hz), risetime, fall-
time, power factor, Watts, VA, VA reactive, phase, pulse
width (pos/neg), dutycycle (pos/neg), temperature °C,
temperature °F, dBV, dBm into 50 Ω and 600 Ω
width modulated motordrives and frequency inverters
Cursor Measurements
Source: Input A, input B or the Mathematical Result
trace (excl. A vs B curve)
Dual horizontal lines: Voltage at cursor 1 and 2,
voltage between cursors
Dual vertical lines: Time between cursors, 1/T
between cursors (in Hz), voltage between markers,
risetime with markers, falltime with markers; Vrms
between cursors (190C only), watts between cursors
(190C only)
Single vertical line: Min-Max and Average voltage
at cursor position; frequency and rms-value of individ-
ual frequency component in FFT result (190C only)
Zoom: Up to 16x horizontal zoom
Recorder Mode
ScopeRecord-Roll Mode
Dual input waveform storage mode
Source and display: Input A, Input B, Dual
Memory depth: 27,500 points per input. Each point
consists of Min-Max pair
Min-Max values: Min-Max values are measured at
high sample rates ensuring capture and display of
glitches
Recording modes: Single sweep, continuous roll,
Start-on-Trigger, Stop-on-Trigger
Stop-on-Trigger (through external): ScopeRecord
mode can be stopped by an individual trigger event, or
by an interruption of a repetitive trigger signal
Horizontal scale: Time from start, time of day
Zoom: Up to 100x
Memory: Up to 2 dual input ScopeRecord waveforms
can be saved for later recall and analysis
TrendPlot
Single or dual input electronic paperless chart recorder.
Plots, displays and stores meter and scope measure-
ments.
Source and display: Input A, Input B or DMM input
Time base range
Recorded timespan
Glitch capture
Sample rate
Resolution
Vpwm ac, Vpwm ac+dc for measurement on pulse
recording
5 ms/div to 1 min/div
200 µsec to 2 sec
6 sec to 24 hr
20 MS/s
50 ns
2 min/div
4.8 sec
250 ns
4 MS/s
48 hr
Memory depth: 18,000 points recording. Per record
point a minimum, a maximum and an average value,
plus a date and timestamp are recorded.
Ranges: 5 s/div to 30 min/div in normal view mode;
5 min/div to 48 hr/div in view all mode, giving
overview of total record
Recorded timespan: Up to 22 days with a resolution
of 1 minute
Recording mode: Continuous roll for the duration of
the full recordable timespan
Measurement speed: 5 measurements per second
Horizontal scale: Time from start, time of day
Zoom: Up to 64x zoom
Memory: Up to 2 TrendPlot recordings can be saved
for later recall and analysis
Cursor measurements - all recorder modes
Source: Input A, B or DMM input
Dual vertical lines: Min-Max or Average
voltage. Time between cursors
Single vertical line: Min-Max or Average
voltage. Absolute date and time or time from start
Meter Mode
Via 4 mm banana inputs. Fully isolated from scope
inputs and scope ground. The specified accuracy is
valid over the temperature range 18 °C to 28 °C
(65 °F to 82 °F). Add 10 % of specified accuracy for
each degree C below 18 °C or above 28 °C.
Maximum Resolution: 5,000 counts
Voltmeter Ranges: 500 mV, 5 V, 50 V, 500 V, 1,000 V
Accuracy:
Ohms:
Ranges: 500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy: ± (0.6 % + 5 counts)
Other Meter Functions
Continuity: Beeper on < 50 Ω (± 30 Ω)
Diode test: Up to 2.8 V
Amps: Adc, Aac, Aac+dc using an optional current
clamp or shunt. Scaling factors: 0.1 mV/A ... 100 V/A
Temperature (°C, °F): With optional accessories. Scale
factors 1 mV/°C or 1 mV/°F
Input impedance: 1 MΩ ± 1% // 10 pF ± 2 pF
Advanced meter functions: Auto/manual ranging,
relative measurements (Zero reference), TrendPlot
recording
Vdc ± (0.5 % + 5 counts)
Vac true rms
Vac+dc true rms
15 Hz...60 Hz: ± (1 % + 10 counts)
60 Hz...1 kHz: ± (2.5 % + 15 counts)
dc...60 Hz: ± (1 % + 10 counts)
60 Hz...1 kHz: ± (2.5 % + 15 counts)
ScopeMeter 190C/190B Series and ScopeMeter 120 Series