MR2 MINIRATOR NTI, MR2 MINIRATOR Datasheet - Page 5

SIGNAL GENERATOR, AUDIO

MR2 MINIRATOR

Manufacturer Part Number
MR2 MINIRATOR
Description
SIGNAL GENERATOR, AUDIO
Manufacturer
NTI
Datasheet

Specifications of MR2 MINIRATOR

Signal Generator Type
Signal
Bandwidth
20kHz
External Height
43mm
External Width
81mm
External Depth
152mm
Sweep Rate Range
0.5s To 5s
Lead Free Status / RoHS Status
na
Technical Data Minilyzer ML1 + Acoustilyzer AL1
Input Connectors
Input Impedance
Input RMS
(upper meas. limit)
Max. DC Input
Residual Noise
Internal Microphone
Monitor Output
Display
Batteries
Dimensions (LxWxH)
Weight
Temperature
Humidity
Technical Data Minilyzer ML1
Frequency
THD+N
vu & PPM (vu-Indicator and Peak Program Meter)
Polarity Test
Signal Balance Error
Sweep
1/3
Scope
Filters
NTI article codes
Minilyzer ML1
Minilyzer ML1 incl. MiniLINK USB PC Interface
Measurements
Level
rd
Octave
Meas. Bandwidth: 10 Hz to 20 kHz
Residual THD+N: balanced
Resolution: 4 digits
Resolution: 3 digits (dB-scale) or 4 digits (%-scale)
Accuracy: < ± 0.1 %
Range: 10 Hz to 20 kHz
XLR balanced, RCA unbalanced
40 kOhm balanced, 20 kOhm unbalanced
+20 dBu balanced, +14 dBu unbalanced
use Adapter -20 dB for balanced levels up to 40 dBu
±50 V
< 12 µV, XLR-input shorted
Omni directional (for polarity and delay measurements only)
Jack 3.5 mm (1/8“), suitable for all common headsets
Backlit graphic LCD, 64 x 100 pixels
3x AA batteries (alkaline)
Typical battery lifetime > 16 hrs
163 x 86 x 42 mm (6.4" x 3.38" x 1.63")
300 g (10.5 oz) incl. batteries
0° to +45° C (32° to 113° F)
< 90 % R.H., non condensing
including 2
unbalanced < -74 dB @
according to IEC 60268 and DIN 45406.
PPM Type I, IIa and Nordic. Both meters with adjustable
reference and with analog & numerical peak-hold readout.
Positive/Negative detection through internal microphone or
XLR/RCA connector. Checks polarity of midrange-speakers,
woofers and cables. MR2 or MR-PRO provides test signal.
Indication range 0.0 % to 100 %
Deviation from perfect balance in % or *1
Level vs. Frequency or
Level and THD+N and Frequency vs. Time
Spectrum acc. IEC 1260, class II and
ANSI S1.11-1976, class II from 50 Hz to 20 kHz,
Bargraph for Level RMS 20 Hz to 20 kHz
Auto triggering, auto ranging, auto scaling
Flat, A-weighting, C-message, Highpass
22 Hz / 60 Hz / 400 Hz, Voice bandpass, X-Curve
Level-RMS, Level-Relative, THD+N, k2...k5, vu+PPM,
Frequency, Polarity, Signal Balance Error, Frequency Sweep,
Time Sweep, 1/3
AFILS measurements supported (with MiniLINK)
Units: dBu, dBV, V
Flatness: ± 0.1 dB
Resolution: 3 digits (dB-scale) or 4 digits (V-scale)
DC
nd
< -85 dB @ -10 dBu to +20 dBu
to 5
rd
th
Octave Spectrum, Scope,
RMS
harmonics analysis
0 dBu to +14 dBu
Accuracy: ± 0.5 % @ 1 kHz
Bandwidth: 20 Hz to 20 kHz
600 000 011
600 000 030
-1
The Minilyzer ML1 is a powerful, complete audio analyzer in a palm-sized format. Its comprehensive set of easy to access measurement
functions simplify the process of system verifi cation, diagnostics and repairs of even very complex audio installations. The smart user
interface aids operators of all skill levels by setting all ranges automatically and providing complete results on a single screen. The op-
tional MiniLINK USB interface supports data storage, documentation and fi rmware updates.
Frequency Sweep
ML1 automatically triggers to a sweep
sequence with any step width and
records the frequency response. The
Minirator MR2 or MR-PRO may be used
as signal source. After capture all sweep
data is available.
THD+N
Supports Total Harmonic Distortion plus
Noise (THD+N) and 2
harmonic distortion as dB value or in %.
Input level and frequency measurement
runs in parallel and the balance indicator
fi nds defective cables.
Level
Continuously measures absolute input
levels either in volts, dBu or dBV
and the signal frequency. Relative
measurements are also supported.
Connecting MiniSPL further supports
basic SPL and LEQ measurements.
nd
to 5
th
selective
Finding wrongly connected speakers is
as simple as moving ML1 into the sound
fi eld of the speaker under test and its
polarity will be displayed. The same
measurement through the XLR input is
ideal for cable tests.
Intermittent faults are often hard to
fi nd. The time sweep records the RMS
level, frequency and the THD+N value
simultaneously, helping to monitor the
audio signal during a long period of
time for later analysis.
Provides a quick and robust look at the
waveform of the balanced audio signal,
quickly fi nding clipping amplifi ers
etc. The auto-scale and auto-trigger
functionality are normally only found
in expensive stand alone scopes.
THD+N, 2nd to 5th Harmonics
Balanced & Unbalanced Input
Frequency and Time Sweeps
High Accuracy (+/- 0.1dB)
Level: RMS, Rel, SPL, LEQ
Scope, vu+PPM, Polarity
Time Sweep
MINILYZER
Polarity
Scope
Analog Audio Analyzer
ML1