ML1 NTI, ML1 Datasheet - Page 2

ANALOG AUDIO ANALYZER

ML1

Manufacturer Part Number
ML1
Description
ANALOG AUDIO ANALYZER
Manufacturer
NTI
Datasheet

Specifications of ML1

Signal Generator Type
Analogue Audio Analyser
Bandwidth
20kHz
External Height
42mm
External Width
86mm
External Depth
140mm
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ML1-821J-471J
Manufacturer:
MOLEX
Quantity:
522
Part Number:
ML100-NSR9805
Quantity:
203
Company:
Part Number:
ML1002
Quantity:
222
Company:
Part Number:
ML1002
Quantity:
222
Part Number:
ML100EL07DR2
Manufacturer:
MOT
Quantity:
1 223
Part Number:
ML100EL07DR2
Manufacturer:
MAXIM
Quantity:
1 224
Part Number:
ML101052
Manufacturer:
NS
Quantity:
6 220
Part Number:
ML1015295-E
Manufacturer:
MICRO
Quantity:
20 000
1
For input levels >20 dBu (balanced) a 20 dB attenuator is available.
CONNECTIONS:
XLR balanced
RCA unbalanced
Microphone (for Polarity measurement only)
3.5mm jack (1/8” , suitable for all common headsets)
WAVEFORMS:
Sinusoidal, Square, White Noise, Pink Noise, Polarity Test
FREQUENCY RANGE
Resolution
Accuracy
SWEEPS:
Capabilities
Speed
Units (accuracy)
LEVEL RANGES
Sine, Square
White Noise
Sweep
Polarity Test
Pink Noise
Resolution
Bandwidth
Flatness
Accuracy
THD+N
Meas. Bandwidth
White Noise
Pink Noise
Output Impedance
Resolution
Residual THD+N
PEAK PROGRAM METER & vu INDICATOR
POLARITY CHECK
SIGNAL BALANCE
SCOPE
FILTERS
RESIDUAL NOISE
DISPLAY
TEMPERATURE RANGE:
0˚C TO 45˚C (32˚ TO 113˚F)
HUMIDITY:
<90% relative non-condensing
BATTERIES
AUTO POWER OFF
DIMENSIONS
WEIGHT
(INCLUDES BATTERIES)
(L x W x H)
1
2 x 1.5 V Dry or NiCd type cell, LR 6, AA, AM3 types
20 Hz - 20 kHz in 1/3 rd Octave steps (Sine)
140 mm x 74 mm x 25 mm (5.5” x 2.9” x 1”)
<-55 dB (0.18%) @ 10mV, 20 Hz - 20 kHz
-76 dBu to +4 dBu
-78 dBV to +2 dBV
-76dBu to +6 dBu
-78 dBV to +4 dBV
0.13 mV to 1.6 V
0.13 mV to 1.25 V
-56 dBu to -4 dBu
1.25 mV to 500 mV
-58 dBV to -6 dBV
<-72 dB (0.025%) typical @ 6 dBu, 1kHz
0.05, 0.5, 1, 2, 3, 4, 5 seconds per step
Range
TECHNICAL DATA
20 Hz - 20 kHz, Crest factor = 2.12
20 Hz - 20 kHz, Crest factor = 3.27
20 hrs continuous operation typical
dBu (±0.5), dBV (±1), V selectable
200 Ohm balanced & unbalanced
2 line LCD (16 characters p/line)
Minirator
20 Hz - 20 kHz for sine
20 Hz sawtooth signal
10, 30, 60 minutes
Generates all
170 g (6 oz)
2dB steps
±0.5 dB
±0.5 dB
X
X
X
X
®
MR1
Steps Inc
2 dBu
±23%
2 dBV
2 dBu
2 dBV
2 dBu
2 dBu
±23%
±23%
Nordic. Both meters with adjustable reference & with analog &
Positive/Negative detection through internal microphone or
XLR/RCA connector. For tweeters, midrange-speakers and
According to IEC 60268 and DIN 45406. PPM Type I IIa &
Frequency sweep, automatically or manually triggered;
3 digits (dB-scale); 4 digits (V-,%-scale or Hz, kHz)
163 mm x 86 mm x 42 mm (6.4” x 3.38” x 1.63”)
Indication range 0.0% to 100%. Deviation from
Parallel measurement of level, THD+N and
Line input RMS (upper measurement limit)
Graphic LCD 64 x 100 pixel, with backlight
unbalanced <-74 dB @ 0 dBu to +14 dBu
Linear A-weighting, C-message, Highpass
balanced <-85 dB @ -10 dBu to +20 dBu
Auto ranging, auto scaling, auto triggering
woofers down to 10 dB S/N input signal
3 digits (dB-scale) or 4 digits (%-scale)
3x AA package dry batteries (alkaline)
22 Hz/60 Hz, 400 Hz voice bandpass
16 hrs continuous operation typical
unbalanced +14 dBu(3.8 V RMS)
Time sweep, manually triggered
balanced +20dBu(7.75 V RMS)
numerical peak-hold readout.
frequency as function of time
300 g (10.5 oz) inc. batteries
<12µ V, XLR-input shorted
perfect balance in % or *1
Minilyzer
3, 10, 30, 60 minutes
±0.5 % @ 1 kHz
10 Hz to 20 kHz
See back page
10 Hz - 20 kHz
20 Hz - 20 kHz
dBu, dBV, V
Analyzes all
< ±0.1%
±0.1 dB
4 digits
X
X
X
X
X
®
RMS
ML1