MC36298 MULTICOMP, MC36298 Datasheet - Page 13

no-image

MC36298

Manufacturer Part Number
MC36298
Description
AXIAL FAN, 60 MM, 27 CFM, 36.5 DBA
Manufacturer
MULTICOMP
Datasheet

Specifications of MC36298

External Height
60mm
External Width
60mm
External Depth
25mm
Current Type
DC
Supply Voltage
12VDC
Current Rating
230mA
Flow Rate
27CFM
Noise Rating
36.5dBA
Bearing Type
VAPO
Flow Rate - Imperial
27CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
V. NOTE
Ⅰ .SAFETY
1. DO NOT use or operate this fan in excess of the limitations set forth in this
2. SUNON recommends adding a protection circuit to the product or application in
3. SUNON recommends installing a protection device to the product or application in
4. This fan must be installed and used in compliance with all applicable safety
5. Use proper care when handling and/or installing this fan. Improper handling or
6. Use proper care during installation and/or wiring. Failure to use proper care may
7. DO NOT use power or ground PWM to control the fan speed. If the fan speed needs
8. For critical or extreme environments, including non stop operation, please contact
specification. SUNON is not be responsible for the non-performance of this fan
and/or any damages resulting from its use, if it is not used or operated in accordance
with the specifications.
which this fan is installed, such as a thermo-fuse, or current-fuse or thermo-protector.
The failure to use such a device may result in smoke, fire, electric shock by
insulation degradation in cases of motor lead short circuit, overload, or over voltage,
and/or other failure.
which this fan is installed if there is a possibility of reverse-connection between
VDC (+) and GND (-). The failure to install such a device may result in smoke, fire,
and/or destruction, although these conditions may not manifest immediately.
standards and regulations.
installation of this fan may cause damage that could result in unsafe conditions.
cause damage to certain components of the fan including, but not limited to, the coil
and lead wires, which could result in smoke and/or fire.
to be adjusted, please contact Sunon to customize the product design for your
application.
Sunon and we will gladly provide assistance with your product selection to ensure an
appropriate cooling product for your application.
SUNONWEALTH
Page 13 of 16
建 準 電 機
2010.10.20

Related parts for MC36298