6
ARM-EVAC 250/500
PORTABLE FUME EXTRACTION SYSTEMS FOR 1 TO 6 WORKSTATIONS
M O R E T H A N 5 0 Y E A R S O F I N D U S T R Y L E A D E R S H I P
The Arm-Evac 250 is ideal for heavy-duty operations that need high capacity and continuous particle fi lter monitoring.
Incorporating microprocessor technology, an easy-to-read graphical LED fi lter condition monitor changes from green to yellow
to red as the fi lter becomes clogged. Additionally, fl ow sensors increase power to the motor as fi lters become blocked to assure
peak performance. The fi lter monitoring system self calibrates using a membrane keypad on the front panel and an audible alarm
alerts the operator when a fi lter change is required. A three-position motor speed button is also on the front panel. A wide variety
of collection accessory options and fi lters are available. An optional silencer/mobile cart is available.
The Arm-Evac 500 is perfectly suited for high performance, cellular manufacturing activities and provides fume extraction for
up to 6 workstations. This unit boasts a high airfl ow motor pump with an effective three-stage fi ltration system. Incorporating
microprocessor technology, an easy-to-read graphical LED fi lter condition monitor changes from green to yellow to red as the fi lter
becomes clogged. The fi lter monitoring system self calibrates using a membrane keypad on the front panel and an audible alarm
alerts the operator when a fi lter change is required. A wide variety of collection accessory options and fi lters are available.
PART NUMBER
POWER REQUIREMENTS
DIMENSIONS
WEIGHT
NOISE LEVEL*
NUMBER OF INLETS
FLOW RATE* GENERAL PURPOSE FILTER
FLOW RATE* CLEANROOM FILTER
NO. OF COLLECTION ACCESSORIES
MAXIMUM DUCT RUN
SYSTEM OPTIONS
STANDARD FILTER
FILTRATION OPTIONS
PART NUMBER
POWER REQUIREMENTS
DIMENSIONS
WEIGHT
NOISE LEVEL*
NUMBER OF INLETS
FLOW RATE* GENERAL PURPOSE FILTER
FLOW RATE* CLEANROOM FILTER
NO. OF COLLECTION ACCESSORIES
MAXIMUM DUCT RUN
SYSTEM OPTIONS
STANDARD FILTER
FILTRATION OPTIONS
SPECIFICATIONS
SPECIFICATIONS
ARM-EVAC 250
8889-0255
115 VAC, 60Hz
393mm H x 282mm W x 365mm D (15.4” H x 11.1” W x 14.3” D)
14 Kg (31 lbs)
58 dBA
Two 75mm (3”)
Single Inlet:
Single Inlet:
Four 45mm (1.75”) or 50mm (2”) or Three 75mm (3”)
5m (16’) per inlet
Silencer/Mobile Cart
General Purpose Filter
General Purpose Filter, Cleanroom Filter, Adhesive Filter, Extended Life Filter, Economy Filter
ARM-EVAC 500
8889-0505
115 VAC, 60Hz
640mm H x 400mm W x 500mm D (25” H x 15.75” W x 19.5” D)
28 Kg (62 lbs)
61 dBA
Three 75mm (3”)
One Inlet:
One Inlet:
Six 45mm (1.75”) or 50mm (2”) or Three 75mm (3”)
5m (16’) per inlet
Silencer/Mobile Cart
General Purpose Filter
General Purpose Filter, Cleanroom Filter
451m
414m
3
3
/h (266cfm);
/h (244cfm);
* Airfl ow and noise level are nominal numbers and will vary based on voltage
* Airfl ow and noise level are nominal numbers and will vary based on voltage
288 m
255 m
3
3
/h (170 cfm);
/h (150 cfm);
Two Inlets:
Two Inlets:
283m
236m
3
3
/h (167cfm) per inlet;
/h (140cfm) per inlet;
Dual Inlet:
Dual Inlet:
8889-0250
230 VAC, 50Hz
8889-0500
230 VAC, 50Hz
ARM-EVAC 250E
ARM-EVAC 500E
170 m
135 m
Three Inlets:
Three Inlets:
3
3
/h (100 cfm) per inlet
/h (80 cfm) per inlet
200m
160m
3
3
/h (119cfm) per
/h (94cfm) per
inlet
inlet
Arm-Evac 250
Arm-Evac 500
The following chart is a quick reference guide for PACE Filtration Systems. Simply select your fume extraction central fi ltration unit
and the type of fi lter you need to identify the part number of the fi lter. (Bold part numbers indicates standard primary
fi lter in Central Filtration Unit).
of fi ltration effi ciencies are available to suit your needs. Lastly, a Gas Filter is included to eliminate any hazardous gases that may
be present. PACE’s gas fi lters use high-grade activated carbon or they combine adsorptive and chemisorptive technologies to
maximize effectiveness. To fully understand your gas fi ltration needs, always consult your Material Safety Data Sheet. The Arm-
Evac 50, 105, 200 & 250 use “Combo Filters” which means that the Primary and Gas fi lters are contained in one fi lter cartridge.
The Arm-Evac 500 uses separate Primary and Gas fi lters which need to be changed individually. Pre-fi lters should be inspected
at least weekly. When they become clogged, they should be replaced immediately to maximize primary fi lter life.
SYSTEM
FX-50
ARM-EVAC 50
ARM-EVAC 105
ARM-EVAC 200
ARM-EVAC 250
ARM-EVAC 500
PRE-FILTER
N/A
8883-0125-P5
8883-0111-P5
8883-0111-P5
8883-0111-P5
8883-0145-P10
HIGH CAPACITY
PRE-FILTER
N/A
N/A
8883-0938-P10* 8883-0871
8883-0938-P10* 8883-0871
8883-0938-P10* 8883-0871
N/A
FILTER TYPE
PRE-FILTERS
ECONOMY FILTERS
GENERAL PURPOSE FILTERS
CLEANROOM FILTERS
HIGH CAPACITY FILTERS
ADHESIVE FILTERS
S O L U T I O N S F O R T H E E L E C T R O N I C S I N T E R C O N N E C T I O N P R O C E S S
ECONOMY
FILTER
8883-0200-P5
8883-0300-P5
N/A
MEET THE NEEDS OF VIRTUALLY ANY APPLICATION
*High Capacity Pre-FIlters must be used in combination with a High Capacity Filter. When Filters need to be replaced, simply remove them from the
GENERAL
FILTER
N/A
8883-0280
8883-0901
8883-0931
8883-0931
8883-0955
FILTER EFFICIENCY RATING
90% ARRESTANCE
EU 4
N/A
N/A
85%
EU 8
99.99%
EU 13
85%
EU 8
N/A
PACE’s Filtration Systems have been specifi cally designed for
application in the electronics industry. A wide variety of fi ltration
options are available for use with PACE Fume Extractors ensuring that
you always have the right fi lter for the job.
Filtration systems for soldering applications are comprised of three
fi lters. As fumes are collected, they fi rst encounter the Pre-Filter, which
is a lower effi ciency particle fi lter that is used to protect the primary
fi lter from large particles, extending the life of the primary fi lter. Next
is the Primary Particle Filter which is a particulate fi lter with large
surface area having effi ciency ratings of 85% and higher. A variety
FUME EXTRACTION FILTERS
Fume Extractor and replace with a new one. Disposal of fi lters should be done in compliance with local environmental regulations.
CLEANROOM
FILTER
N/A
8883-0290
8883-0921
8883-0921
8883-0921
8883-0965
RECOMMENDED APPLICATION
Recommended for use with all fi ltration systems.
Recommended for soldering applications where cost-effective
solutions are required. Ideal for applications where coarse
dust is generated.
Recommended for soldering applications where normal volumes
of fumes are being generated for 1 or 2 shifts.
Recommended for applications in Cleanroom environments
or where the highest fi ltration effi ciency is required.
Recommended for soldering applications where heavy volumes
of fumes are generated or where operations are running 3 shifts.
Filter contains additional fi ltration media and will last longer.
Recommended for any bench-top application utilizing adhesives,
solvents, or cleaners used in small quantities and not in open
containers or “baths”.
HIGH CAPACITY
FILTER
N/A
N/A
8883-0936*
8883-0936*
8883-0936*
N/A
CARBON
FILTER
N/A
N/A
N/A
N/A
N/A
8883-0956
ADHESIVE
FILTER
N/A
8883-0295
8883-0951
8883-0951
88830951