Specifications of 350A-1

Time Range
2min To 2h
Colour
White
Contact Current Max
16A
Current Rating
16A
Mounting Type
Surface Mount
No. Of Inputs
2
Supply Voltage Max
240VAC
For Use With
Lighting, Heating, Ventilation
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
INSTALLATION NOTES
N.B If the mains power has not been applied and the push button/touch pad is pressed the blue locator ring will flash once.
The unit will then revert to the rapid flashing mode and the sequence must be repeated.
N.B From the rapid flashing mode, if the installation sequence is not progressed, the unit will revert to sleep mode after a
period of 10 minutes. To re-activate the unit press and hold the push button/touch pad for approximately 5 seconds.
OUTDOOR INSTALLATION
Please note only products in the Elkay energy outdoor range are suitable for use outdoors. Elkay energy outdoor can only
be used in conjunction with the surface mount box supplied.
Take the surface mount box and remove knock out section. If required and to ensure IP66 waterproof rating, please use a
suitable M20 cable gland. Mount the surface mount box on a secure surface using the mounting pack supplied. Place screw
cover seals over the mounting screws.
Turn off mains supply before proceeding with installation - Install as per previous timer instructions - Mount unit onto
surface mount box using the fixing screws at all four corners - Place screw hole seals over left and right screw cavities - Clip
on front fascia plate - Re-instate mains supply.
OPERATION
1. Press the push button/touch pad and the red LED will light up. Your light source or appliance will now be switched on.
2. At any time during the working of the light source or appliance, the push button/touch pad can be pressed to reset the
timing sequence to the originally set time. E.g when the timing period is 30 minutes, if push button/touch pad is pressed 15
minutes into the sequence, the timer will re-set for a further 30 minutes.
3. To end the timing sequence prematurely, press and hold the push button/touch pad until the red LED flashes
continuously indicating the last minute of operation. Your light source or appliance will be switched off, after one minute.
4. At one minute prior to the end of the timing sequence, the red LED will begin to flash continuously for the last minute of
operation. The blue locator ring will then illuminate once the light source or appliance has gone off.
OPERATION NOTES
If the Elkay timer does not receive power for a period of over seven days, please turn battery off, using switch 4.
In the case of power failure, your Elkay timer will attempt to automatically re-start, which will cause the blue locator ring to
flash. The unit will attempt to locate the power source for a total of five minutes. Each recovery attempt will increase by a
minute each time. This will be repeated 25 times before the unit will power down to sleep mode. During this time, pressing
and holding the push button/touch button for approximately 10 seconds will initiate a further recovery attempt.
IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IEE Wiring
Regulations. If unit is faulty return to place of purchase.
TECHNICAL HELPLINE
For further help, or information on this and the other products in the Elkay range visit www.elkay.co.uk or call 01675 468222.
Elkay Electrical, Coleshill, Birmingham, England.
Tel: +44 (0) 1675 468222 www.elkay.co.uk
Patent Pending Inst. Ref. No PT201 Rev. No.: 04/07