ETU17 TIMEGUARD, ETU17 Datasheet - Page 8

TIME SWITCH, PLUG-IN, 7DAY

ETU17

Manufacturer Part Number
ETU17
Description
TIME SWITCH, PLUG-IN, 7DAY
Manufacturer
TIMEGUARD
Datasheet

Specifications of ETU17

Contact Type
ON/OFF
Time Range
7day
Contact Current Max
13A
External Depth
41mm
External Length / Height
81mm
External Width
60mm
Controller Output
Digital
Svhc
No SVHC (15-Dec-2010)
For Use With
Fluorescent Lighting, Filament Lighting, Motor
Having reached the clock time and day or programme time and day(s) requiring
change, press the <Change> button briefly to initiate programme mode and then
follow sections 2 and 3 as required. Having completed the change press and hold
down the <Program> button until normal operating mode is reached and then release.
6. Cancelling Programmes
Any ON/OFF programme can be cancelled by clearing its ON and OFF time
separately. Follow step 5 and when the ON programme to be cancelled is displayed
press the <Change> button briefly and the day dot(s) will flash, press the
<Program> button briefly to select the hours and press the <Change> button until
the hour digits show -- --: then press the <Program> button briefly to clear the
programme time. The display will show the hour and minute dashes and ON
flashing. Repeat the procedure for the OFF time.
7. Programming Across Midnight
This can be achieved by programming the required ON time in the initial day and
6
the required OFF time in the subsequent day. The unused times in these two
programmes can either be left blank (--:--) or used for an OFF time during the
initial day and an ON time during the subsequent day.
8. Self Cancelling Override
To change the output status from ON to OFF or vice versa press the <Change>
button whilst in normal operating mode. The output status will change and indicate
override is in operation by flashing either the ON or OFF symbol on the display. The
override will end at the next programmed change, or sooner, if the <Change> button
is pressed again.