P3356 ETAL, P3356 Datasheet - Page 4

TRANSFORMER, V.90, 56K

P3356

Manufacturer Part Number
P3356
Description
TRANSFORMER, V.90, 56K
Manufacturer
ETAL
Datasheet

Specifications of P3356

Transformer Type
Matching
Approval Bodies
EN60950
External Depth
18mm
External Length / Height
12.6mm
External Width
18mm
Inductance
6H
Isolation Voltage
3kV
Mounting Type
PCB
Turns Ratio
1
Dc
RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P3356
Manufacturer:
JAE
Quantity:
5 000
ETALDOC 591/11
Insertion Loss (Line to RXA): 2.8dB @ 2kHz
Frequency Response : ±0.2dB 30Hz – 10kHz
Return Loss: 20dB 200Hz – 4kHz
Transhybrid Loss: 30dB 50Hz – 10kHz
600
Insertion Loss: 1.5dB @ 2kHz
Frequency Response : ±0.2dB 20Hz – 20kHz
Return Loss: 16dB 20Hz – 20kHz
Constructed in accordance with IEC 60950-1,
EN 60950-1,
insulation, 250Vrms maximum working voltage,
flammability class V-0.
There are no special installation requirements
(beyond attending to usual PCB track separations)
since the integral cover provides supplementary
insulation from its external faces to internal core
and windings.
* If no DC block required, one of these capacitors can be removed and
SAFETY
the other set to 22 F, or, if preferred, both capacitors can be eliminated.
600 Ω
600Ω
Fig. 8
Fig. 6
600 Ω
Ω Ω Ω Ω
LINE
600
Instrumentation
47 F*
µ
µ
22 F
10nF
and
6.8nF
µ
UL 60950-1,
1k
10k
6.8nF
47 F*
560
µ
supplementary
1nF
Improved matching and hybrid
600 Ω
RXA
TXA2
TXA1
Page 4 of 6
Patented
Insertion Loss (Line to RXA): 2.2dB @ 2kHz
Frequency Response : ±0.5dB 50Hz – 4kHz
Return Loss: 20dB 200Hz – 4kHz
Transhybrid Loss: 18dB 200Hz – 4kHz
Certified under the IEC CB scheme (Certificate
DK-8570) to IEC 60950-1-2001, sub-clauses 1.5,
1.5.1, 1.5.2, 1.7.1, 2.9, 2.9.1, 2.9.2, 2.9.3, 2.10,
2.10.1, 2.10.2, 2.10.3, 2.10.3.1, 2.10.3.3, 2.10.4,
2.10.5, 2.10.5.1, 2.10.5.2, 2.10.5.4, 4.7, 4.7.1
(classV-1), 4.7.3, 4.7.3.1, 4.7.3.4, 5.2, 5.2.1, 5.2.2,
6.1.2.1
deviations) for a maximum working voltage of
250Vrms, nominal mains supply voltage not
exceeding 300Vrms and a maximum operating
temperature of 70ºC in Pollution Degree 2
environments.
Certified to EN 60950-1:2001 (Demko Certificate
140243-01).
Recognized under the Component Recognition
Program of Underwriters Laboratories Inc. to US and
Canadian
No. 60950-1-03/UL60950-1, First Edition, based on
IEC 60950-1, First Edition, maximum working
voltage
(clearance), Pollution Degree 2, supplementary
insulation.
UL File number E203175.
Additionally, Profec Technologies certifies all
transformers as providing voltage isolation of
2.12kVrms, 3kV DC minimum. All shipments are
supported by a certificate of conformity to current
applicable safety standards.
*Note: 100nF capacitor should have a temperature stable dielectric
CERTIFICATION
European CTR21/(Australia, etc.)
Fig. 7
(220)
270
(120nF)
150nF
(820)
LINE
(Finland,
750
180Vrms
requirements
10nF
22 F
µ
Norway,
(creepage),
CAN/CSA
1k
10k
Sweden
120
December 2005
P3356
420V
100nF*
750
1nF
national
C22.2
peak
TXA1
TXA2
RXA

Related parts for P3356