5011 Staco Energy Products Company, 5011 Datasheet - Page 3

Variable Transformer

5011

Manufacturer Part Number
5011
Description
Variable Transformer
Manufacturer
Staco Energy Products Company
Type
Variable Transformersr
Datasheet

Specifications of 5011

Input Voltage
120V
Output Current
50A
Knob Rotation
CW
Transformer Mounting
Bench
Secondary Current Nom
50A
No. Of Phases
Single
Primary Voltages
120V
Power Rating
7kVA
Peak Reflow Compatible (260 C)
No
Dimensions
5.56 in L x 13.88 in W x 15.69 in H
Product
Variable Transformers
Height
15.69 in
Length
5.56 in
Width
13.88 in
Constant Current Load
50A
Rohs Compliant
Yes
Current Rating
50A
Leaded Process Compatible
No
Output Voltage
140V
Output Voltage Max
140VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5011
Manufacturer:
INTEL
Quantity:
3
Part Number:
5011
Manufacturer:
KEYSTONE
Quantity:
20 000
Part Number:
501100B00000G
Manufacturer:
ATH
Quantity:
3 000
Part Number:
5011025001+
Manufacturer:
OK
Quantity:
1 140
Part Number:
501147
Manufacturer:
ST
0
Part Number:
501175-1192
Manufacturer:
ERICSSON
Quantity:
86
Part Number:
5011751192
Manufacturer:
PANASONIC
Quantity:
7 000
5000 Series
MANUALLY
OPERATED
5011E-4PS M5011E-4PS
5021E-4PS
5011E-6PS M5011E-6PS
5021E-3P
5021E-3Y
5011E-4D
5011E-4P
5011-4PS
5021E-4D
5021E-4P
5021-4PS
5011E-5P
5011E-6D
5011E-6P
5011-6PS
5011E-6Y
5021-3P
5021-3Y
5011-4D
5011-4P
5021-4D
5021-4P
5011-5P
5011-6D
5011-6P
5011-6Y
VIEW FROM ROTOR END
PART NUMBER
M5011E-4D
M5021E-4D
M5021E-PS
M5011E-6D
M5021E-3P
M5021E-3Y
M5011E-4P
M5011-4PS
M5021E-4P
M5021-4PS
M5011E-5P
M5011E-6P
M5011-6PS
M5011E-6Y
M5021-3P
M5021-3Y
M5011-4D
M5011-4P
M5021-4D
M5021-4P
M5011-5P
M5011-6D
M5011-6P
M5011-6Y
MOTOR
DRIVEN
5011
Open Delta
Open Delta
Open Delta
WIRING
Parallel
Parallel
Parallel
Parallel
Parallel
Parallel
Parallel
Single
Phase
Phase
Phase
Single
Phase
Single
Phase
Series
Phase
Single
Phase
Single
Phase
Series
Single
Phase
Phase
Single
Phase
Single
Phase
Series
Phase
Three
Three
Three
Three
Three
Wye
Wye
VOLTS
240
120
480
240
120
120
240
240
120
240
120
480
240
120
120
120
240
240
INPUT
HERTZ
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
60
60
60
VOLTS
0-280
0-140
0-140
0-280
0-280
0-560
0-140
0-140
0-140
0-240
0-280
0-480
0-560
0-560
0-280
0-240
0-280
0-240
0-280
0-480
0-560
0-280
0-280
For opposite rotation interchange external
connections from 5 to 1, 2 to 4 and 6 to 7.
5021 Single Unit
OUTPUT
112*-48
84*-36
28*-12
56*-24
56*-24
AMPS
MAX
V. D.
V. D.
V. D.
V. D.
100
200
100
112
112
V.D.
250
150
300
150
100
84
84
28
28
56
56
56
56
10.2‡
11.8‡
11.8‡
13.5‡
13.5‡
23..3
MAX
20.2
23.5
27.2
24.2
28.0
28.0
23.3
27.2
26.9
31.4
26.9
31.4
35.0
36.4
42.0
42.0
48.5
KVA
INCREASE
ROTATION
VOLTAGE
SHAFT
FOR
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
TERMINAL CONNECTIONS
As Viewed from Rotor End
INPUT
4-4-4
2-2-2
5-5-5
2-1-2
4-1-4
2-1-2
5-1-5
2-1-2
2-2-2
1-4
1-2
1-5
1-2
2-2
1-4
1-2
1-5
4-4
2-2
5-5
1-2
1-2
2-2
For Increasing Voltage
OUTPUT
5021 Ganged Unit
B-1-B
B-1-B
B-1-B
B-1-B
D-1-D
B-B-B
3-3-3
3-3-3
3-3-3
D-D
1-D
1-D
1-D
1-D
B-B
1-D
1-D
1-D
B-B
B-B
B-B
1-D
1-D
(Pg 8 & 9)
SCHE-
MATIC
20 & 6
21 & 5
21 & 4
21 & 5
21 & 4
22 & 5
22 & 4
21 & 6
22
22
22
22
22
MAN-
481
483
481
479
UAL
216
212
314
316
314
314
316
314
400
NET WEIGHT
IN LBS.
(MAX)
MOTOR
DRIVEN
237
233
335
337
335
335
337
335
420
502
504
502
500