Specifications of J6609

End To Ground Resistance
1Mohm
No. Of Studs
3
Svhc
No SVHC (18-Jun-2010)
Colour
Yellow
No. Of Stud Size 1
1
No. Of Stud Size 2
2
Stud Size 1
10mm
Stud Size 2
4mm
Terminal Type
Stu
Lead Free Status / RoHS Status
na
© 2007 VERMASON LTD.
“All EBP shall be marked or labelled.” (EN 61340-5-1
paragraph 4.4 Marking of EPA bonding points [EBP])
“An easily accessible dedicated EBP [EPA ground
bonding point] for the wrist strap shall be established
adjacent to each working area, or working surface. A
sufficient number of EBP shall be provided for
operators and visitors.” (EN 61340-5-1 section 5.3.3)
A. The Vermason Slim EBP Bar has been designed to be installed underneath bench tops where
B. With a width of only 15mm it is especially suitable for benches with narrow edges. The
C. Connect earthing cord to a suitable earth. A spare ring terminal is supplied if the cord needs
D. Resistors are usually built-in to each connector. The normal earth contact is linked via
E. Per EN 61340-5-2 paragraph 5.1.1 "A nominal 1 megohm resistor is commonly used in wrist
F. The operator connects the wriststrap to the stud via a coiled cord. A second stud can be used
Item
231345
231350
231360
it will be accessible to all connecting ground cords and where it is unlikely to be knocked and
damaged or hinder the operator.
product is supplied with reverse-mounted screws held in position by self-retaining washers,
thereby making the installation process simple. The distance between screw centres is
89mm. The design of the ABS plastic moulding provides strength to the assembly and the
rounded corners ensure comfort during use for the operator.
to be shortened.
individual 1MΩ resistor rated at 1/2W. In the event of a workstation element becoming live the
resistor will limit the fault current to less than 0.3mA at 240V. The resistor is capable of
withstanding 500VDC for 6 minutes.
straps and to ground work surfaces. In the event of an operator touching an energized
conductor, for the normal mains electricity supplies this resistor will limit the current flowing
through the person to less than 0.5mA. Current limiting or cut-off devices should also be
considered and in some areas may be demanded by legislation."
to connect a working surface. The third connection is available for guest use or to ground
another item such as a trolley. Periodic verification of the ground path should be part of the
ESD control program.
Description
Slim EBP Box with 3 x 10mm Studs
Slim EBP Box with 3 x 10mm Studs, No Resistor
Slim EBP Box with 3 x 4mm Plug Studs
Slim EBP Boxes
E-MAIL:Service@Vermason.co.uk, INTERNET: Vermason.co.uk
PHONE: +44 (0) 1462-672005, FAX: +44 (0) 1462-670440
1 AVENUE ONE, LETCHWORTH, HERTS, SG6 2HB UK
VERMASON LTD.
Drawing Number
231345
Made in Britain
May 2007
DATE: