8891 3M, 8891 Datasheet - Page 104

Static Dissipative Rubber Table Runner

8891

Manufacturer Part Number
8891
Description
Static Dissipative Rubber Table Runner
Manufacturer
3M
Datasheet

Specifications of 8891

Ground Terminals
Stud
External Width
4ft
Thickness
1.7mm
Roll Length
40ft
Color
Blue
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
88911-5201
Quantity:
137
Part Number:
8891CPBNG6NA3
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
8891CPCNG7C36
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
3M
Item
Dimensions
Weight
High Voltage Power Supply (internal)
Low Voltage Power Supplies
Operating Time (rechargeable batteries)
Storage Memory Capacity
Response Time
Impedance
Accuracy
Operating Functions
Interfaces
Displays
Settings — CPM* Operating Function
Static Decay Time
Offset-Voltage Time
Voltmeter Operating Function
Fieldmeter Operating Function
Plate Electrode
Cup Electrode
Selection of Operating Function
Operating Temperature
Humidity
Storage Temperature
*Charge Plate Monitor
Charge Analyzer 711 Properties
Typical Properties
Base unit: 6 H x 6 W x 6 in. L (15.2 x 15.2 x 15.2 cm)
3.53 lbs. (1.6 kg)
> 1100 V positive or negative (current limiting resistor: 10M ohm)
Built-in NiMH-rechargeable batteries, 1400 mAh
AC/DC Adapter: secondary side, DC 12 V/500 mA
4 hours (approximately) with full charge
128 k EEPROM (e.g. sufficient for approximately 100 CPM*-measurements)
0 to 100%; 100 ms
10
± 2.5% of range end value (digitized)
± 5% for the analog output (for 1000 V range)
± 10% for the analog output (25, 100, 500 and 5000 V ranges)
CPM* (positive/negative/automatic), voltmeter and fieldmeter
Analog output ± 2 V (± 1 V, in 500 V range for voltmeter), serial PC-COM, and external field
sensor type 711 RS
Two, 11-segment positive and negative LED-bar charge indicators
16-digit alphanumeric dual row LCD
Starting voltage: 600 V – 1200 V in 1 V-steps
Stop voltage: 1 V – 500 V in 1 V-steps (in decimal mode)
0.1 seconds – 99.9 seconds
1 – 10 seconds in 1 second steps and 10 – 60 seconds in 10 second steps
Ranges: 25 V, 100 V, 500 V, 1.0 kV, 5.0 kV and auto range
Ranges: Manual 1.25 kV/m, 5 kV/m, 25 kV/m, 50 kV/m, 250 kV/m, and automatic
SS-steel (152 x 152) mm/(6 x 6) inches, removable, capacitance (20 ± 2) pF
Gold-plated electrode with 4 mm-banana socket, for voltage measurements
Pre-setting is “FIELDMETER,” additional automatic settings by applying the plate or cup electrode
32°F to 113°F (0°C to 45°C)
Maximum 60%
Note: At high relative humidity, charge leakage may occur affecting the decay time measure-
ment
-22°F to 140°F (-30°C to 60°C)
15
ohm (Teflon
-separators cleaned)