ADP124-3.3-EVALZ Analog Devices Inc, ADP124-3.3-EVALZ Datasheet - Page 6

no-image

ADP124-3.3-EVALZ

Manufacturer Part Number
ADP124-3.3-EVALZ
Description
CMOS Linear Regulator Eval. Board
Manufacturer
Analog Devices Inc
Datasheets

Specifications of ADP124-3.3-EVALZ

Silicon Manufacturer
Analog Devices
Application Sub Type
LDO
Kit Application Type
Power Management - Voltage Regulator
Silicon Core Number
ADP124
Channels Per Ic
1 - Single
Voltage - Output
3.3V
Current - Output
550mA (Max)
Voltage - Input
2.3 ~ 5.5 V
Regulator Type
Positive Fixed
Operating Temperature
-40°C ~ 85°C
Board Type
Fully Populated
Utilized Ic / Part
ADP124
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADP124-3.3-EVALZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
UG-056
Figure 7, Figure 8, and Figure 9 show how the evaluation boards
can be connected to a voltage source and a voltage meter for
basic out-put voltage accuracy measurements. A resistor can be
used as the load for the regulator. Ensure that the resistor has a
power rating that is adequate to handle the power that is
expected to dissipate across it. An electronic load can also be
used as an alternative. Ensure that the voltage source can supply
enough current for the expected load levels.
Follow these steps to connect to a voltage source and voltage meter:
1.
2.
3.
Connect the negative terminal (−) of the voltage source to
one of the GND pads on the evaluation board.
Connect the positive terminal (+) of the voltage source to
the VIN pad of the evaluation board.
Connect a load between the VOUT pad and one of the
GND pads.
VOLTAGE SOURCE
+
Figure 9. ADP124/ADP125 Output Voltage Measurement Setup, LFCSP
Rev. B | Page 6 of 12
4.
5.
6.
When these steps are completed, the voltage source can be turned
on. If J1 is inserted (connecting EN to VIN for automatic startup),
the regulator powers up.
If the load current is large, the user must connect the voltage
meter as close as possible to the output capacitor to reduce the
effects of IR drops.
Connect the negative terminal (−) of the voltage meter to
one of the GND pads.
Connect the positive terminal (+) of the voltage meter to
the VOUT pad.
If the
Otherwise, install R1 and R2 for the
LDO.
ADP124
Evaluation Board User Guide
LFCSP board is being used, short R1.
VOLTMETER
+
1.99711
LOAD
ADP125
adjustable