TYPHOON-800 RF Solutions, TYPHOON-800 Datasheet
TYPHOON-800
Specifications of TYPHOON-800
Related parts for TYPHOON-800
TYPHOON-800 Summary of contents
Page 1
... RS232 or RS485 serial cable replacement • Machine to machine data communications • Description The RF Solutions typhoon RF modem provides fast and reliable wireless data communications at an exceptionally competitive price. Whilst the RF modem is simple to use it is also highly adaptable and can be used in a wide variety of applications. ...
Page 2
... Standard Commands Description............................................................................... 9 3.2 Transparent Mode............................................................................................................ 10 3.3 Addressed Secured mode................................................................................................ 10 Register Definitions ........................................................................................................................ 12 4 Radio.................................................................................................................................... 12 4.1 RS-232/485 Serial Link .................................................................................................... 12 4.2 Operation.......................................................................................................................... 13 4.3 Network Control ............................................................................................................... 13 4.4 Radio Test Commands .................................................................................................... 14 Ordering Information....................................................................................................................... 14 DS510-1 Aug 2008 M ADIO ODEM Contents ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Page 2 ...
Page 3
... DS510-1 Aug 2008 M ADIO ODEM Technical Specification Typical 869.400 to 869.650 ETSI 300 220 ERC-REC 70-03 Min Typical 19,200 ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 J4 J5 TB3 TB2 ANT1 TB1 LED1 RF Module LED4 LED5 LED2 LED3 LED6 MDM500-868N GFSK 800 Max Units dBm - ...
Page 4
... Conditions Min Ripple <50mV 6.5V Transmit 30 (27dBm/500mW) Receive 27 TB3 Cable entry POWER 1.5 Host Interface ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Max Units -102 dBm - - -10 dBm - dB Typical Max 12V 13 Pin Connection 5 0V (ground 12Vdc, 1A max J4, 3-4 Operation ...
Page 5
... ODEM Pin TB1 Cable entry 3 Additional Detail To the host From the host 0V From the host To the host ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 RX Pin 2 TX Pin 3 GND Pin 5 RTS Pin 7 CTS Pin 8 Name Description TB2 GND Ground, 0 Vdc RX Receive data. ...
Page 6
... Additional Detail To the host To the host 0V From the host From the host J4, 5-6 Fitted Not Fitted ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Name Description TB2 GND Ground, 0Vdc RXB Receive data ‘-‘ the host RXA Receive data ‘+’ ...
Page 7
... Operation at maximum ratings for extended periods may affect the reliability of this product 5 All dimensions are approximate and exclude the antenna and any fixings DS510-1 Aug 2008 M ADIO ODEM 3 . ˚ ˚ - +85 C ˚ ˚ - +55 C Height 144mm Width 168mm Depth 85mm 125mm x 90mm x 1.6mm ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Page 7 ...
Page 8
... Apply button. You can also change the configuration settings by entering AT commands into the terminal window in MTC workbench. Please refer to the sections for a description of the AT commands available. DS510-1 Aug 2008 M ADIO ODEM Software Specification ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Page 8 ...
Page 9
... Windows HyperTerminal 'AT/V’: Display values of the modem software version Information concerning the version number and installation date is sent on the serial link DS510-1 Aug 2008 M ADIO ODEM Operating Modes Additional command ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 <CR> ... Page 9 ...
Page 10
... Example: "1=Hello" sends the data frame "Hello" to modem with address 1 The modem with address ‘1’ recognises the client transmitting modem by the number starting • the data frame. DS510-1 Aug 2008 M ADIO ODEM ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Page 10 ...
Page 11
... Maximum of clients per network = 255, maximum of networks = 255. • In this mode the RF modem can be configured to scan the radio link for activity and verify it is free before transmission (listen before talk) thereby avoiding data collisions. DS510-1 Aug 2008 M ADIO ODEM ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Page 11 ...
Page 12
... Hardware: CTS/RTS • 2 None (default) • Indicates the maximum frames size that will be given to the Modem. When this size is reached, the modem resets Buffer Size the RTS signal. Between 30 and 240 Default : 230 ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Page 12 ...
Page 13
... Included between 0 and 255 Default: 2 Name Description Indicates the modems receive Address. Client Number Between 0 and 255 Default: 0 Indicates the default address to which every radio frame Default will be sent. Addressee Default: 0 (inactive) ©2008 Reg. No. 227 4001, ENGLAND TYPHOON 800 Page 13 ...
Page 14
... E=Error The commands are effective after a maximum delay of 10 ms. A new command can be entered • after the current command has been acknowledged by the modem Part Number TYPHOON-800 PSU-12V1AIN-IP For more information or general enquiries, please contact Email sales@rfsolutions.co.uk DS510-1 Aug 2008 ...