48040 Loctite, 48040 Datasheet - Page 2

ETHYL CYANOACRYLATE ADH, BOTTLE 20G

48040

Manufacturer Part Number
48040
Description
ETHYL CYANOACRYLATE ADH, BOTTLE 20G
Manufacturer
Loctite
Series
480r
Datasheet

Specifications of 48040

Adhesive Type
Ethyl Cyanoacrylate
Color
Black
Dispensing Method
Bottle
Weight
20g
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Inhalation:
Skin contact:
Eye contact:
Ingestion:
Notes to physician:
Flash point:
Autoignition temperature:
Flammable/Explosive limits-lower %:
Flammable/Explosive limits-upper %:
Extinguishing media:
Special fire fighting procedures:
Unusual fire or explosion hazards:
Hazardous combustion products:
Environmental precautions:
Clean-up methods:
Item No. :
48040
Remove to fresh air. If discomfort persists seek medical attention.
Do not pull bonded skin apart. Soak in warm soapy water. Gently peel apart using a blunt instrument.
If skin is burned due to the rapid generation of heat by a large drop, seek medical attention. If lips are
bonded, apply warm water to the lips and encourage wetting and pressure from saliva in mouth. Peel or
roll lips apart. Do not pull lips apart with direct opposing force.
Immediately flush with plenty of water for at least 15 minutes. Get medical attention. If eyelids are
bonded closed, release eyelashes with warm water by covering with a wet pad. Do not force eye open.
Cyanoacrylate will bond to eye protein and will cause a lachrymatory effect which will help to debond
the adhesive. Keep eye covered until debonding is complete, usually within 1-3 days. Medical attention
should be sought in case solid particles of polymerized cyanoacrylate trapped behind the eyelid caused
abrasive damage.
Ensure breathing passages are not obstructed. The product will polymerize rapidly and bond to the
mouth making it almost impossible to swallow. Saliva will separate any solidified product in several
hours. Prevent the patient from swallowing any separated mass.
Surgery is not necessary to separate accidentally bonded tissues. Experience has shown that bonded
tissues are best treated by passive, non-surgical first aid. If rapid curing has caused thermal burns they
should be treated symptomatically after adhesive is removed.
80ºC (176ºF) to 93.4ºC (200ºF)
485°C (905°F)
Not determined
Not determined
Water spray (fog), foam, dry chemical or carbon dioxide.
Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA).
None
Trace amounts of toxic fumes may be released on incineration and the use of breathing apparatus is
recommended.
Ventilate area.
Do not use cloths for mopping up. Flood with water to complete polymerization and scrape off the floor.
Cured material can be disposed of as non-hazardous waste.
6. ACCIDENTAL RELEASE MEASURES
5. FIRE-FIGHTING MEASURES
4. FIRST AID MEASURES
2 of 5
Tagliabue closed cup
Product name: 480 Prism
Instant Adhesive, Black Toughened