490NAD91103 SQUARE D, 490NAD91103 Datasheet

PROFIBUS PLC CONNECTOR, PLUG, 9POS

490NAD91103

Manufacturer Part Number
490NAD91103
Description
PROFIBUS PLC CONNECTOR, PLUG, 9POS
Manufacturer
SQUARE D
Series
NADr
Datasheet

Specifications of 490NAD91103

Connector Type
Programmable Logic Controller
Gender
Plug
No. Of Contacts
9
Connector Mounting
Cable
For Use With
Square D Altivar 71 Profibus DP Drives
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Catalog
2004
TeSys®
U-Line Motor Starters
File 8502
CONTENTS
Description
General Information and Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Power Base Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Communication and Function Modules . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Altistart Soft Starts for TeSys U-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Dimensions, Mounting, and Schematics . . . . . . . . . . . . . . . . . . . . . . . . . 40
Application Examples. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Terms and Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Catalog Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Page

490NAD91103 Summary of contents

Page 1

... U-Line Motor Starters File 8502 CONTENTS Description General Information and Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Power Base Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Communication and Function Modules . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Altistart Soft Starts for TeSys U-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Dimensions, Mounting, and Schematics . . . . . . . . . . . . . . . . . . . . . . . . . 40 Application Examples Terms and Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Catalog Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Page ...

Page 2

...

Page 3

Examples of Various U-Line Components Door Interlock Mounting Kit 09/2004 GENERAL INFORMATION AND SELECTION 10 ® TeSys U-Line motor starters provide motor control for choices ranging from a basic motor starter with solid-state thermal overload protection ...

Page 4

... Select a function module or communication module (optional) from the tables on pages 27 - 33. 4. Select an auxiliary contact block (optional) from the table on page 26. 5. Select one or more accessories (optional) from the table on pages 36 & 39. Accessories include: — Current limiter/isolator module — Incoming line phase barrier for UL 508 Type E compliance (Self-Protected Combination Motor Controller). — ...

Page 5

Power Bases Starter LUS Self- protected starter LUB Blanking Cover LU9C1 1 Short circuit protection provided by LUB self-protected starter only. LUS starter requires customer provided short circuit protection per national and local electric codes. 2 See page 27 for ...

Page 6

TeSys® U-Line Motor Starters General Information and Selection Power Bases Starter LUS Self-protected starter LUB Status of Overload / power short circuit poles fault indication and manual reset Blanking Auxiliary Fault Diff. Cover Contact Manual Reset LU9C1 Module Module 2 ...

Page 7

Power Bases Starter LUS Self-Protected Starter LUB Blanking Cover LU9C1 1 Short circuit protection provided by LUB self-protected starter only. LUS starter requires customer provided short circuit protection per national and local electric codes. 2 See page 27 for complete ...

Page 8

... LU•S12, LU•S32 and Accessories E164862 NLDX LUALB1 meets the essential requirements of the LV and EMC directives. LR43364 3211-08 LU•B12, LU•B32 and Accessories LR43364 3211-04 LU•S12, LU•S32 LR43364 3211-08 LUALB1 IEC/EN 60947-6-2, CSA C22-2 no. 14, Type E UL 508 Type E: (LUtB12, LUtB32 with LU9SP0 incoming line phase barrier) ...

Page 9

Power Base and Control Unit Type Power Circuit Connection Characteristics Screw Clamp Terminals - AWG Conductor Size 1 conductor Stranded cable without cable end 2 conductors 1 conductor Stranded cable with cable end 2 conductors 1 conductor Solid cable without ...

Page 10

TeSys® U-Line Motor Starters Characteristics Specific Characteristics of Power Bases LU2B or LU2S and Reverser Blocks LU2M or LU6M Without change of direction Maximum operating time With change of direction General Characteristics of all Auxiliary Contacts Conventional rated thermal For ...

Page 11

Characteristics of Standard Control Units LUCA Motor type Protection Conforming to standard Tripping class conforming to UL 508, IEC/EN 60947-6-2 Frequency limits of the operating current Overload protection Ambient temperature range Protection against phase imbalance Tripping threshold Short-circuit protection Tripping ...

Page 12

TeSys® U-Line Motor Starters Characteristics Characteristics of Limiter Isolator Module LUALB1 Rated insulation voltage (Ui) conforming to standard IEC/EN 60947-1 Conventional rated thermal current (Ith) conforming to standard IEC/EN 60947-1 Operating threshold Breaking capacity Mounting Screw Clamp Terminals - AWG ...

Page 13

Characteristics of Thermal Overload Pre-alarm Function Module LUFW10 Activation threshold Hysteresis between activation and switching off Display Supply Digital output characteristics Characteristics of Motor Load Indication Function Module LUFV2 Analog output Signal delivered Load impedance Signal characteristics with advanced control ...

Page 14

TeSys® U-Line Motor Starters POWER BASE SELECTION The U-Line motor starter consists of one power base (selected from this page) and one control unit (select from page minimum. The power bases are available in two ...

Page 15

... Must order control terminal block LU9MR1. Must order control terminal block LU9M1 or pre-wired coil connector LU9MRC. Control Terminal Blocks 2 Description 3 Coil terminal 4 Control block Pre-wired Control Connection Accessories For control connections between a power base and a direct mount reversing block. Description Reversing prewiring connector 09/2004 Three Phase Max. (hp max.) ...

Page 16

TeSys® U-Line Motor Starters Power Base Selection Use in Category AC-41 per IEC 60947 (previously IEC 947 AC- 0.8 0.6 0 ...

Page 17

Use in Category AC-44 per IEC 60947 (previously IEC 947 AC-4) Ue ≤ 440 V 1 0.8 0.6 0.5 0.4 0.3 0.2 0.1 0.08 0.06 0.05 0.04 0.03 0.02 0. 09/2004 Ue = 690 ...

Page 18

TeSys® U-Line Motor Starters Power Base Selection Short-Circuit Ratings for Power Base LUB U = 460 V e 100 0.4 0.6 0 Maximum peak current power base LUB32 3. 12 ...

Page 19

CONTROL UNITS Function Characteristics Control Units Overload Protection Magnetic Trip Overcurrent Protection 2 Short-Circuit Protection Phase Loss Protection Phase Imbalance Protection Ground Fault Detection (equipment protection only) Overload Trip Class Motor Type (AC only) Test Function Overtorque (Jam) Underload Long ...

Page 20

Control Units LUCA LUCB LUCC LUCD 20 © 2004 Schneider Electric All Rights Reserved Standard and Advanced Control Units Description 1 Extraction and locking handle 2 Test button (on advanced control unit only) 3 Adjustable ...

Page 21

LUCM••BL XBTNU400 09/2004 Multifunction Description 1 Extraction and locking handle 2 Built in display window (2 lines, 12 characters) 3 4-button keypad 4 24 Vdc auxiliary power input 5 RS-485 external communication port. Connection ...

Page 22

TeSys® U-Line Motor Starters Control Units Tripping Curves for Control Units LUCA, LUCB, LUCD Average operating times at 70 °F (20 °C) according to multiples of the setting current, tolerance: ± 1000 1 100 ...

Page 23

Tripping curves for control unit LUCM Cold state curves Average operating times at 70 °F (20 °C) according to multiples of the setting current, tolerance: ± 10000 1000 100 09/2004 ...

Page 24

TeSys® U-Line Motor Starters Control Units Tripping Curves for Control Unit LUCM Hot state curves Average operating times at 70 °F (20 °C) according to multiples of the setting current, tolerance: ± 10000 1000 100 10 1 0.1 ...

Page 25

COMMUNICATION AND FUNCTION MODULES PowerSuite™ Software PowerSuite™ software is a Windows™ -based program providing an intuitive, graphical user interface for the ® TeSys U-Line LUCM multifunction control units, Altivar ® Altivar 58 (ATV58) drive controllers, and Altistart run on: • ...

Page 26

... N.O. contact indicating that control handle is in “ready” position and 1 N.C. fault signaling contact 1 N.O. contact indicating that control handle is in “ready” position and 1 N.O. fault signaling contact Accessories Description Screw clamp terminal blocks 1 1 Blanking cover 2 Control circuit contact block 1 Blanking cover is included with every power base and starter only base ...

Page 27

... Auxiliary Contact Function Modules Module with 2 contacts indicating state of LUB or LUS power base power poles. For use with 250 Vac or Vdc Connection 2 N.O. Contacts 1 N.O., 1 N.C. Contacts 2 N.C. Contacts Accessories Description 1 Blanking cover 1 Blanking cover is included with every power base. Communication and Function Modules ...

Page 28

TeSys® U-Line Motor Starters Communication and Function Modules Parallel Wiring Module Architecture 4 To PLC To 24 Vdc The parallel wiring system makes it possible to connect power bases to the PLC I/O modules quickly and without any need for ...

Page 29

LUB + LUFC00 + LU9BN11C 1 8 LU2B + LUFC00 + LU9MRC 4 LU9G02 09/2004 Connection of Parallel Wiring Module Output Terminals to the Power Base Coil Terminals By pre-wired connector or removable screw terminal: • Pre-wired connector: Pre-wired components ...

Page 30

TeSys® U-Line Motor Starters Communication and Function Modules AS-i Communication Module Serial Type Connection The AS-i communication module makes it easy to connect power bases to the AS-i wiring system, allowing remote control and command of these power bases. The ...

Page 31

LUB + ASILUF C5 + LU9BN11C 1 5 LU2B + ASILUF C5 + LU9MRC XZMC11 ASITERV2 Configuration example with Premium TSXSAY100/1000 module 09/2004 Communication and Function Modules Connection of AS-i Communication Module Output Terminals to the Power Base ...

Page 32

TeSys® U-Line Motor Starters Communication and Function Modules ® Modbus Series Type Connection Communication module LULC031 enables the U-Line power base to be connected to the Modbus network. It must have a 24 Vdc supply and must be used in ...

Page 33

LUB + LUL C031 + LU9B 1 7 LU2B + LUL C031 + LU9M 6 4 LU9GC3 09/2004 Communication and Function Modules ® Connection of Modbus Communication Module Output Terminals to the Power Base Coil Terminals By pre-wired ...

Page 34

TeSys® U-Line Motor Starters Communication and Function Modules Communication Gateways LUFP communication gateway allows connection between Modbus DeviceNet. After configuration, these gateways manage information which can be accessed by the Modbus network and make this information available for read/write functions ...

Page 35

... LUFP9 0.54 (0.245) Weight Catalog Number lb (kg) VW3A8306D30 0.330 (0.150) VW3A8306R03 0.110 (0.050) VW3A8306R10 0.110 (0.050) VW3A8306R30 0.330 (0.150) TSXFPACC12 0.088 (0.040) 490NAD91104 – 490NAD91103 – Weight Catalog Number lb (kg) LU9CD1 0.048 (0.022) © 2004 Schneider Electric All Rights Reserved 35 ...

Page 36

... Schneider Electric All Rights Reserved ACCESSORIES Pre-wired System for Power Connections Suitable for group motor installations only Pitch Description Application inches (mm) 1.77 (45) 2 power bases 2.12 (54) 1.77 (45) 3 power bases Set of 3-pole 2.12 (54 busbars 1.77 (45) 4 power bases 2.12 (54) 5 power bases 2 ...

Page 37

... Door Interlock Mounting Kit and Handles for use with LUB•• and LU2B•• Description 2 Mounting Kit Handle kit (black/blue) NEMA Type 12/3R Handle kit (red/yellow) NEMA Type 12/3R Other Accessories Clip-on – identification markers 1 LUALB1 supplied with LUALF1 limiter cartridge. LUB, LU2B power bases are rated for 480 V/60 Hz/42 kA short circuit breaking capacity ...

Page 38

TeSys® U-Line Motor Starters ALTISTART Overview While Altistart 01 soft starts can be used with almost any motor starter, it now adds soft start and soft stop motor 1 control to the TeSys U-Line family of motor starters. When either ...

Page 39

Description The Altistart 1 • 1 green LED (4) to indicate that soft start power is ON • 1 yellow LED (5) that will illuminate 10 seconds after a start command has been given indicating that the soft start’s voltage ...

Page 40

TeSys® U-Line Motor Starters DIMENSIONS, MOUNTING, AND SCHEMATICS Power Bases Non-Reversing LUB12, LUB32, LUS12, LUS32 DIN Rail mounting 5.0 5.0 126 126 X2 X2 1.77 5.31 5.31 45 135 (1) 135 (1) Minimum electrical clearance 1.38" (35 mm) ...

Page 41

Current Limiter Isolator Module LUALB1 and LUB•• Control Circuit Contact Block LUA8E20 0.35 9 2.12 54 Door Interlock Mounting Kit LU9AP00 / LU9AP11 / LU9AP12 AS-i Addressing Consoles XZMC11 3.15 80 ® Modbus Hub LU9CG3 5.04 128 09/2004 1.77 45 ...

Page 42

TeSys® U-Line Motor Starters Dimensions, Mounting, and Schematics Power Bases For additional wiring information refer to pages 53 - 56. Non-reversing 3-phase motor LUB/LUS LUC Control Unit 13-14 N.O. auxiliary contact 12-22 N.C. auxiliary contact With ...

Page 43

Control units For additional wiring information refer to pages 53 - 56. Standard control unit LUCA Basic internal scheme Power Base Sensor Interface L1 Control Sensor A.S.I.C. 2 Sensor L3 Supply and Thermal Detection of ...

Page 44

TeSys® U-Line Motor Starters Dimensions, Mounting, and Schematics For additional wiring information refer to pages 53 - 56. Thermal Overload Pre-Alarm Function Module LUFW10 LUFW 10 Basic internal scheme Input interface Bi-stable Relay 250 Vac Vdc ...

Page 45

Communication Modules For additional wiring information refer to pages 53 - 56. Communication module ASILUFC5 Without pre-wired coil connector ASILUFC5 24 Vdc With pre-wired coil connector LU9BN11C ASILUFC5 24 Vdc LU9BN11C Connector With pre-wired coil connector LU9MRC ASILUFC5 24 Vdc ...

Page 46

TeSys® U-Line Motor Starters Dimensions, Mounting, and Schematics Communication Modules Parallel wiring module Without pre-wired coil connector LUFC00 Parallel bus Module Link // RJ45 With pre-wired coil connector LU9BN11C Parallel bus Module LUFC00 Link // RJ45 ...

Page 47

Data Profile under AS-i Control Unit Status Commands Register Addresses Accessible under Modbus Control Unit Identification Register 0–Register 99 Log Register 100–Register 450 Status Register 451–Register 464 Register 465–Register 473 Values Register 474–Register 599 Configuration Register 600–Register 699 Commands Register ...

Page 48

© 2004 Schneider Electric All Rights Reserved APPLICATION EXAMPLES Application Control and protection of a motor (pump, fan, etc.) Operating Conditions • Power 480 V • FLA: 7.5 A • Class 10 overload protection ...

Page 49

M 3 09/2004 Application Upgrading of an existing installation (from previous page) to meet the operating conditions described below. Operating Conditions Monitor the status of the motor and obtain alarm signaling by an integrated mechanical contact, in order to improve ...

Page 50

Application Examples 50 © 2004 Schneider Electric All Rights Reserved Application Control and protection of a packing machine conveyor belt. Operating Conditions • Power: 0 480 V • FLA: 1.0 A • Utilization category: AC-43 • Two wire ...

Page 51

M 3 Modbus profile IEC 64915 Commands Status (Register 704) (Register 455) Forward running Bit 0 Ready (available) Reverse running Bit 1 Poles closed Reserved Bit 2 Fault Reset Bit 3 Alarms Reserved Bit 4 Reserved Connection test Bit 5 ...

Page 52

Application Examples © 2004 Schneider Electric All Rights Reserved Application Control and protection of a reversing motor (Example: 2-position turntable). Operating Conditions • Power 480 V • FLA: 7.5 A • Maximum of 1 ...

Page 53

Non-Reversing Power Base LUB LUB Control Unit M 3 LUB/LUS 2-Wire Control, with 2-Position Selector Switch L1 Off On (+) LUB/LUS Control Circuit Contact Block LUA8E20 + Power Bases LUB or LUB2 24 ...

Page 54

TeSys® U-Line Motor Starters Application Examples (continued) Non-Reversing Power Bases LUB, LUS Control via AS-i Communication Module ASILUFC5 Without pre-wired coil connector With emergency stop 24VDC (+) AS-i Module ASILUFC5 24 Vdc LMB/LUS Maintained Stop Control via ...

Page 55

Power Bases LUB + Reversing Block LU6M LUB Control Unit LU6M M 3 LUB/LUS + LU6M 3-wire control, momentary start push button with holding contact L1 LU6M Maintained Forward Stop Reverse 09/2004 Power Base LUS + Reversing Block LU6M Customer ...

Page 56

TeSys® U-Line Motor Starters Application Examples Reversing Power Bases LU2B LU2B Control Unit M 3 LU2B/LU2S 2-wire control via 3-position switch L2 L1 LU2B/LU2S Reversing Motor Controller Off For Rev Control via communication module ASILUFC5 Without pre-wired ...

Page 57

TERMS AND DEFINITIONS The low oxygen atmosphere at high altitudes reduces the dielectric strength of the air and hence the rated operational voltage of the contactor. It also reduces the cooling effect of the air and hence the rated operational ...

Page 58

TeSys® U-Line Motor Starters 58 © 2004 Schneider Electric All Rights Reserved 09/2004 ...

Page 59

... INDEX LUA1C110 LUA1C20 Numerics LUA1C200 LUA8E20 35 490NAD91103 LUALB1 35 490NAD91104 LUALF1 A LUB12 LUB120 29 ABFH20H100 LUB32 29 ABFH20H200 LUB320 29 ABFH20H300 LUCA05 36 AK5JB144 LUCA12 36 AK5PC13 LUCA12FU 36 AK5PC33 LUCA18 36 AK5PC33L LUCA1X , 30 50 ASILUFC5 LUCA1XBL , 31 50 ASITERV2 LUCA32 G LUCA32FU LUCAX6 36 GV1G09 LUCB05 36 GV1G10 LUCB12 36 GV2G245 LUCB12FU 36 GV2G254 ...

Page 60

Schneider Electric USA Schneider Electric Canada 8001 Highway 64 East 19 Waterman Avenue, Knightdale, NC 27545 M4B 1 Y2 1-888-SquareD Toronto, Ontario (1-888-778-2733) 1-800-565-6699 www.us.SquareD.com www.schneider-electric.ca 8502CT0201R6/04 © 2004 Schneider Electric All Rights Reserved Replaces 8502CT0201 dated 07/03 09/2004 ...