02 02 160 2202 HARTING, 02 02 160 2202 Datasheet - Page 18

no-image

02 02 160 2202

Manufacturer Part Number
02 02 160 2202
Description
SOCKET, BACKPLANE, 160WAY
Manufacturer
HARTING
Series
Har-bus 64r
Datasheet

Specifications of 02 02 160 2202

Connector Type
Series
Pitch Spacing
2.54mm
No. Of Contacts
160
Gender
Socket
No. Of Rows
5
Rows Loaded
Z + A + B + C + D
Contact Termination
Press Fit
Contact Material
Copper Alloy
Rohs Compliant
Yes
Contact Plating
Gold
No. Of Mating Cycles
250
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
06 .
20
Technical characteristics
Number of contacts
Contact spacing (mm)
Working current
Clearance and creepage
Working voltage
Test voltage U
Contact resistance
Insulation resistance
Temperature range
Electrical termination
Insertion and withdrawal force
Materials
Contact surface
1)
2)
Details see chapter 04
Explanation of performance levels see chapter 00
minimal clearance and creepage distance
see current carrying capacity chart
The working voltage also depends
on the clearance and creepage
dimensions of the pcb itself
and the associated wiring
Male connector
Diameter of pcb plated through holes
pcb thickness
Recommended pcb holes
for press-in technology
Female connector
Mouldings
Contacts
Contact zone
between two contacts
between two rows
(in a row)
r.m.s.
clearance
clearance
creepage
creepage
160
2.54
1 A at 70 °C
and all contacts
are loaded
according to the safety
regulations of the equipment
Explanations see chapter 00
1 kV
≤ 20 mΩ
≥ 10
– 55 °C … + 125 °C
Compliant press-in
termination
chapter 04
≥ 1.6 mm
in acc. to EN 60 352-5
Solder pins for pcb
connection Ø 1.0 ± 0.1 mm
according to IEC 60 326-3
≤ 160 N
Thermoplastic resin,
glass-fibre filled, UL 94-V0
Copper alloy
Plated acc. to performance
level
See recommendation
male connector
10
2)
Ω acc. to IEC 60512-2
1.4
1.4
1.2
1.2
distance in mm
female connector
0.6
0.6
0.8
0.8
1)
Current carrying capacity chart
The current carrying capacity is limited by maximum temperature of
materials for inserts and contacts including terminals. The current
capacity curve is valid for continuous, non interrupted current loaded
contacts of connectors when simultaneous power on all contacts is
given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512
Ambient temperature
inverse
complementary
to IEC 61076-4-113

Related parts for 02 02 160 2202