115.265.24 ENTRELEC UK, 115.265.24 Datasheet

TERMINAL BLOCK, DIN, 35A, GREY

115.265.24

Manufacturer Part Number
115.265.24
Description
TERMINAL BLOCK, DIN, 35A, GREY
Manufacturer
ENTRELEC UK
Series
5000r
Datasheet

Specifications of 115.265.24

Connector Type
DIN Terminal Block
Connector Mounting
DIN Rail
Pitch Spacing
6mm
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
CSA
Colour
Grey
Connector Mounting Orientation
DIN Rail
Technical catalogue
1SLC805001D0201
Gemini
Low voltage electric
insulating switchboards

Related parts for 115.265.24

115.265.24 Summary of contents

Page 1

Technical catalogue 1SLC805001D0201 Gemini Low voltage electric insulating switchboards ...

Page 2

ABB SACE Table of contents Introduction Order codes Technical information Overall dimensions Code list ...

Page 3

ABB SACE is one of the forerunners among the companies in the Group in dedicating considerable resources towards reaching its objectives of sustainable development and environmental protection. This is confirmed by the fact ...

Page 4

Plant in Marostica (Vicenza-Italy) ...

Page 5

...

Page 6

ABB SACE Introduction Index Characteristics of Gemini switchboards ................................................................................ 1/2 1 1/1 ...

Page 7

Introduction Characteristics of Gemini switchboards Gemini, something completely different in switchboards ABB SACE’s Gemini range is revolutionizing the market of low 1 voltage electric insulating switchboards. The reason for this is that it is the first switchboard made in thermoplastic ...

Page 8

...

Page 9

Introduction Characteristics of Gemini switchboards Nothing can be compared with Gemini, even when the switch- boards have reached the end of their life cycle: they are totally ecologically compatible. The material used to manufacture 1 them is 100% recyclable. Poly- ...

Page 10

...

Page 11

Introduction Characteristics of Gemini switchboards A switchboard that is not just one system, but three Gemini is the result of design work conducted by ABB with the direct collaboration of 1 switchboard manufacturers, in- stallers and designers who con- sidered ...

Page 12

ABB SACE 1 ...

Page 13

...

Page 14

ABB SACE Order codes Index Basic configuration ................................................................................................................. 2/2 Components for automation applications ............................................................................... 2/6 Components for distribution and mixed applications ........................................................... 2/10 Accessories .......................................................................................................................... 2/16 Rapid selection table ............................................................................................................ 2/20 2 2/1 ...

Page 15

Characteristics IP66 (IEC EN 60529) PROTECTION Class II insulation STRENGTH Thermoplastic material moulded in co-injection Resistance to abnormal heat and fire temperature of 750 °C (IEC EN 60695-2-1) IK10 (IEC EN 50102) degree ...

Page 16

Order codes Basic configurations In the basic configuration, tools; the fact that they open at Gemini switchboards are com- an angle of more than 180° posed of boxes in six different means that it is easy to work on sizes ...

Page 17

Order codes Basic configurations Boxes and doors • Available in 6 sizes • Single order code combined with box and transparent and opaque door • Pack with door dismounted and wrapped separately • Door designed so that it can be ...

Page 18

Order codes Basic configurations Size Single box Size Single doors Rapid selection table ......................... page 2/20 ABB SACE Internal dimensions External dimensions Conf./Imb. WxHxD (mm) WxHxD (mm) 335x400x210 ...

Page 19

base automation distribution accessories ...

Page 20

Order codes Components for automation applications Gemini switchboards are de- applications, not only is it pos- signed to be perfectly compa- sible to select the box and door tible with ABB components for in the required size, but you can ...

Page 21

Order codes Components for automation applications Base plates • Available in three versions in blank or drilled metal and insulating material • Positioning at 3 different depths for size 1, 4 different depths for sizes 2-3-4 and 7 different depths ...

Page 22

Order codes Components for automation applications Code Wiring ducts • Made in self-extinguishing thermoplastic material (UL 94 V0), resistant to abnormal heat and fire up to 960 °C (IEC 695-2-1) • RAL 7035 grey color • Available in version with ...

Page 23

base automation distribution accessories ...

Page 24

Order codes Components for distribution and mixed applications In distribution and mixed appli- cations, the Gemini switchboard is designed to be fitted with Sy- stem pro M modular devices and Tmax moulded-case circuit breakers. The frame is the load-bearing element ...

Page 25

Order codes Components for distribution and mixed applications Uprights • Incorporated vertical wiring duct (ABB patent) • Snap-on mounting of all components (installation pitch of 75 mm) • Snap-on insertion into box • Depth of installed components adjusted at a ...

Page 26

Order codes Components for distribution and mixed applications Size of the switchboard Drilled panels • Supplied with DIN rail complete with supports to snap onto uprights and adjustable in depth • Available in 1 module (H 150 mm) and 1+1/2 ...

Page 27

Order codes Components for distribution and mixed applications Size of the switchboard Partial modular plates • Available in 1 module (H 150 mm) and 2 module (H 300 mm, sizes 2-6) dimensions • Snap-on mounting onto uprights with depth adjustment ...

Page 28

Order codes Components for distribution and mixed applications Size of the switchboard Wiring kit • Composed of wiring duct in versions 25x60 mm and 40x60 mm (WxH, 8-12 mm slots) and Fix-O-Rapid • Snap-on mounting on uprights with depth adjustment ...

Page 29

base automation distribution accessories ...

Page 30

Order codes Accessories Gemini switchboards have the and pedestal make it easier to same accessories for both au- install the switchboards in any tomation and distribution appli- context. cations, ensuring maximum ver- Three different kinds of locks are satility and ...

Page 31

Order codes Accessories • Available in three versions with ciphered key and handle, with triangular and square impressions 2 Mounting elements • Guarantee optimum wall, pole and floor mounting conditions Ventilation kit • Composed of plastic grills and filter to ...

Page 32

Order codes Accessories Code Anti-condensation kit • Kit in special material to prevent condensation from forming inside the switchboard: it include GORE • Impermeable to water (pressure): 1 bar • Air flow: 68/h ( mbar) • 1 kit ...

Page 33

Order codes Rapid selection table Basic configuration No Size installable No. of DIN modules vertical mod. dimensions (mod. x row) (H=150 mm 400 24 (12x2 550 54 (18x3 (18x4) 4 700 ...

Page 34

Order codes Rapid selection table Components for automation Inner door Base plate Blank Drilled Insulating 1SL0259A00 1SL0275A00 1SL0267A00 - 1SL0260A00 1SL0276A00 1SL0268A00 1SL0252A00 1SL0261A00 1SL0277A00 1SL0269A00 1SL0253A00 1SL0262A00 1SL0278A00 1SL0270A00 1SL0254A00 1SL0263A00 1SL0279A00 1SL0271A00 1SL0255A00 1SL0264A00 1SL0280A00 1SL0272A00 1SL0256A00 Accessories ...

Page 35

...

Page 36

ABB SACE Technical information Index Compliance with Standards and technical characteristics ...................................................... 3/2 IP degree of protection ............................................................................................................ 3/4 IK degree of resistance to impacts .......................................................................................... 3/5 Double insulation .................................................................................................................... 3/6 Self-extinguishing tests ........................................................................................................... 3/6 Resistance to chemical agents ............................................................................................... ...

Page 37

Technical information Compliance with Standards and technical characteristics Reference Standards Standard CEI EN 50298 (“Empty enclosures for low voltage switch-gear and control gear assem- blies. General requirements.”) is the prescriptive reference for Gemini switchboards. The object of Standard CEI EN ...

Page 38

Technical information Technical characteristics Table of Gemini switchboards’ technical characteristics Size Gemini with transparent door 1SL0211A00 Gemini with opaque door 1SL0201A00 External dimensions WxHxD (mm) 335x400x210 Internal dimensions WxHxD (mm) 250x300x180 IP degree IP66 Double isolation Yes IK degree 10 ...

Page 39

Technical information IP degree of protection IP degree of protection As indicated in the following table, the IP degree of protection is expressed by two characteristic numbers depending on the beha- vior of the product to which it refers according ...

Page 40

Technical information IK degree of resistance to impacts IK degree of resistance to impacts The IK degree is expressed in Joules in compliance with Standard CEI EN 50102 protection against impacts 0. Resistance to ...

Page 41

Technical information Double insulation and self-extinguishing tests Double insulation Double insulation guarantees that Gemini is protected against indirect contacts on condition that the manufacturer’s instructions are observed when carrying out mounting and wiring operations on the switchboard and that the ...

Page 42

Cold w Hot wa Sulfuric Hydroc Acetic Benzol Gasolin Aceton Ethyl a Ammon Dichlor Diesel Minera Food o Perchlo Trichlo Ethylet Toluene Methan Wine Fruit ju Laundr Deterg ...

Page 43

Technical information Integration with ABB products Installation of Tmax moulded-case circuit breakers The table indicates the type of installation required for the different versions of Tmax moulded-case circuit breakers in Gemini switchboards. Before carrying out wiring operations check compliance with ...

Page 44

Technical information Integration with ABB products Unifix L fast wiring system Unifix is the system patented by ABB for the fast and safe wiring of equipment in the System pro M range and Tmax and Isomax moulded-case circuit breakers. It ...

Page 45

Technical information Integration with ABB products Electrical connection systems Member of ABB Group MA 2,5/5 Pitch (mm) 5 Maximum section 3 ( 2,5 Connection 0115 486.03 Neutral 0125 486.05 Protection 0165 488.27 Term. Plate 0118 368.16 Head separator ...

Page 46

Technical information Integration with ABB products M 6/8. 0115 501.12 0115 278.01 - 0125 278. 0116 656.25 0114 195.06 0113 482.05 - 0163 043. 0173 060.00 0007 865.26 0007 865.26 ...

Page 47

Technical information Examples of orders Examples of orders The selection of components for the configuration of Gemini switchboards depends on the space available and the type of applica- tion. Two examples for each size are given below. 3 Size 1 ...

Page 48

Technical information Examples of orders Size 3 Distribution/Mixed 1SL0213A00 Box + transparent door 1SL0285A00 Uprights 1SL0336A00 Kit for Tmax 1SL0308A00 (x2) Drilled panel 1 mod. + DIN rail 1SL0291A00 DIN rail 1SL0325A00 Blank panel 1 mod. See pages 3/10-3/11 Entrelec ...

Page 49

Technical information Examples of orders 3 Size 5 Distribution/Mixed 1SL0215A00 Box + transparent door 1SL0286A00 Uprights 1SL0337A00 Kit for Tmax 1SL0303A00 Modular plate 2 mod. 1SL0332A00 Blank panel 2 mod. 1SL0314A00 Drilled panel 1+1/2 mod. 1SL0320A00 Blank panel 1/2 mod. ...

Page 50

Technical information Component mounting distances Component mounting distances The reference mounting distances between components for the functional configuration of Gemini switchboards are shown in the diagrams. Automation components distance size mounting plate/floor MIN. MAX. 1 16.3 ...

Page 51

Technical information Component mounting distances distance drilled size panel/door Measurements are expressed in millimeters 3/ distance drilled panel/floor size 1 145 ...

Page 52

Technical information Disposal instructiones Information about how to dispose of Gemini switchboards when they reach the end of their life Instructions are given below about the procedures to adopt when disposing of Gemini switchboards at the end of their life ...

Page 53

Technical information Disposal instructiones Section III – Components to be removed from the product and sent for separate treatment Refer to section II of the table for a description of the materials. Notes for recovery and disposal At the end ...

Page 54

ABB SACE Overall dimensions Index Basic configuration .................................................................................................................. 4/2 Components for automation applications ................................................................................ 4/5 Components for distribution and mixed applications .............................................................. 4/6 4 4/1 ...

Page 55

Overall dimensions Basic configuration Front view Size 1 335 = 150 = code 1SL0201A00 - 1SL0211A00 - 1SL0221A00 Size 4 4 590 = = 286 code 1SL0204A00 - 1SL0214A00 - 1SL0224A00 Top view Size 1 250 335 Size 4 500 ...

Page 56

Overall dimensions Basic configuration Side view 210 180 Size 1 260 230 Size 4 Installation with brackets 195 395 Size 1 Size 2 445 645 Size 5 Size 6 ABB SACE 260 230 260 230 Size 2 Size 3 360 ...

Page 57

Overall dimensions Basic configuration External opaque and transparent doors w Sizes 4/4 w size w 1 325 2 450 3 450 4 575 5 575 6 825 Sizes locks d = distance ...

Page 58

Overall dimensions Components for automation applications Base plates Blank and insulating w drilled d size 235 285 2 360 435 360 585 4 485 585 485 735 6 735 885 ...

Page 59

Overall dimensions Components for distribution and mixed applications Uprights Size Size 6 4/6 Size 2 Sizes Size 5 upright duct size 132 152 ...

Page 60

Overall dimensions Components for distribution and mixed applications DIN rail 35 22.5 pos. 2 size A pos. 1 210 63 63.5 2 318 51 63.5 3 318 51 63.5 4 443 51 63.5 5 443 51 63.5 663 ...

Page 61

Overall dimensions Components for distribution and mixed applications Blank panels 2 modules w 1/2 module b 1/2 mod. size 250 375 75 3 375 75 500 500 75 750 6 75 ...

Page 62

Overall dimensions Components for distribution and mixed applications Modular plates 1 module b 2 modules w 12.5 73.7 54.7 19 67.2 79.7 92.2 104.7 117.2 Drilled panel 1 module 2 modules size 130 210 - ...

Page 63

Overall dimensions Components for distribution and mixed applications Wiring kit Duct 25x60 Duct 40x60 Ventilation kit 4 130 23 Ø 4.5x4 104.5 Pole installation kit size A 1 232 2-3 358 ...

Page 64

ABB SACE Code list 5 5/1 ...

Page 65

Code list Code 05 019 05 033 05 035 05 037 05 043 05 045 05 047 05 049 05 051 05 053 05 063 05 065 05 067 05 069 05 071 05 073 05 083 05 085 05 ...

Page 66

Code list Code 1SL0272A00 1SL0275A00 1SL0276A00 1SL0277A00 1SL0278A00 1SL0279A00 1SL0280A00 1SL0283A00 1SL0284A00 1SL0285A00 1SL0286A00 1SL0287A00 1SL0290A00 1SL0291A00 1SL0292A00 1SL0293A00 1SL0296A00 1SL0297A00 1SL0298A00 1SL0299A00 1SL0302A00 1SL0303A00 1SL0304A00 1SL0307A00 1SL0308A00 1SL0309A00 1SL0310A00 1SL0313A00 1SL0314A00 1SL0315A00 1SL0318A00 1SL0319A00 1SL0320A00 1SL0321A00 1SL0324A00 1SL0325A00 1SL0326A00 ...

Page 67

...

Page 68

ABB SACE S.p.A. Enclosures and Cable Systems Viale Vicenza, 61 36063 Marostica (VI) - Italy Tel.: ++39 0424 478200 - Telefax: ++39 0424 478310 http://www.abb.com Due to possible developments of standards as well as of materials, the characteristics and dimensions ...

Related keywords