MCHP06W2F1002T5E MULTICOMP, MCHP06W2F1002T5E Datasheet - Page 3

RESISTOR, HIGH POWER, 10KOHM, 500mW, 1%

MCHP06W2F1002T5E

Manufacturer Part Number
MCHP06W2F1002T5E
Description
RESISTOR, HIGH POWER, 10KOHM, 500mW, 1%
Manufacturer
MULTICOMP
Series
HP06r
Datasheet

Specifications of MCHP06W2F1002T5E

Resistance
10kohm
Resistance Tolerance
± 1%
Power Rating
500mW
Voltage Rating
50V
Resistor Element Material
Thick Film
Temperature Coefficient
± 100ppm/°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCHP06W2F1002T5E
Manufacturer:
AVX
Quantity:
30 000
Performance specification
Temperature coefficient
Short time overload
Terminal bending
Dielectric withstanding
voltage
Solderability
Soldering heat
Temperature cycling
Load life in humidity
Load life
HP06 Series High Power Resistors
Characteristics
≤ 10E: ±200PPM/°C
> 10E: ±100PPM/°C
Resistance change rate is
±5% (2.0% + 0.1Ω) maximum
±1% (1.0% + 0.1Ω) maximum
± (1.0% + 0.05Ω) maximum
No evidence of flashover mechanical
damage, arcing or insulation break down
Minimum 95% coverage
Resistance change rate is ±(1%+0.05Ω)
maximum
5% (1.0% + 0.05Ω) maximum
±1% (0.5% + 0.05Ω) maximum
Resistance change rate is
±5% (3.0% + 0.1Ω) maximum
±1% (1.0% + 0.1Ω) maximum
Resistance change rate is
±5% (3.0% + 0.1Ω) maximum
±1% (1.0% + 0.1Ω) maximum
Limits
Page <3>
Resistance change after continuous 5 cycles for duty
cycle specified below:
Natural resistance change per temperature degree
centigrade
R2-R1/ R1 (t2-t1) x 10
R1
R2
Test pattern
Permanent resistance change after the application of a
potential of 2.5 times RCWV for 5 seconds.
Clamped in the trough of a 90°C metallic V-BLOCK
and shall be tested at AC potential respectively
specified in the type for 60-70 seconds.
Test temperature of solder
Soldwe
Dip The Resistor Intoa Solder Bath Having a
Temperatuer of 260°C ±3°C and hold it for 10±1
Seconds.
Twist of Test Board : Y/X = 3/90 mm for 60 seconds.
Resistance change after 1000 hours
(1.5 hours "on", 0.5 hour "off") at RCWV
in a humidity chamber controlled at
40°C ±2°C and 90 to 95% relative humidity.
Permanent resistance change after 1000 hours
operating at RCWV with duty cycle of
(1.5 hours "on", 0.5 hour "off") at 70°C ±2°C ambient.
Step
1
2
3
4
: Resistance value at room temperature (t1)
: Resistance value at room temperature plus
100°C (t2).
Temperature
-55°C ±3°C
Room temperature
+155°C ±2°C
Room temperature
Test Methods (JIS C 5201-1)
: Room temperature(t1),
Room temperature+100°C(t2)
6
(PPm/°C).
: 245 ±3°C; dipping
: 2-3 seconds.
Time
30 minutes
10 to 15 minutes
30 minutes
10 to 15 minutes
time in
03/05/08 V1.1

Related parts for MCHP06W2F1002T5E