MCHV05WAJ0104T5E MULTICOMP, MCHV05WAJ0104T5E Datasheet - Page 3

RESISTOR, HV, 100KOHM, 100mW, 5%

MCHV05WAJ0104T5E

Manufacturer Part Number
MCHV05WAJ0104T5E
Description
RESISTOR, HV, 100KOHM, 100mW, 5%
Manufacturer
MULTICOMP
Series
HV05r
Datasheet

Specifications of MCHV05WAJ0104T5E

Resistance
100kohm
Resistance Tolerance
± 5%
Power Rating
100mW
Voltage Rating
300V
Resistor Element Material
Thick Film
Temperature Coefficient
± 200ppm/°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Performance specifications
Temperature coefficient
Short time overload
Humidity (Steady State)
Terminal bending
Temperature cycling
Load life in humidity
Load Life
Solderability
HV05 Series High Voltage Resistors
Characteristics
±200 PPM/°C
∆R ≤ ±(2.0% + 0.1Ω) maximum
∆R ≤ ±(3.0% + 0.1Ω) maximum
∆R ≤ ±(1.0% + 0.05Ω) maximum Twist of Test Board : Y/X = 3/90 mm for 60 seconds.
5%:∆R ≤ ±(1.0% + 0.05Ω)
maximum
∆R ≤ ±(3.0% + 0.01Ω) maximum
∆R ≤ ±(3.0% + 0.01Ω) maximum
95% coverage minimum
Go up tin rate bigger than half of
end pole.
Limits
Page <3>
Reflow:
Natural resistance change per temperature degree centigrade
R2-R1/ R1 (t2-t1) x 10
R1
R2
Test pattern
Permanent resistance change after the application of a
potential of 2.5 times RCWV for 5 seconds.
Resistance change after continuous 5 cycles for duty
cycles specified below
Step 1 : 30 minutes at -55 ±3°C
Step 2 : 10 to 15 minutes at room temperature
Step 3 : 30 minutes at 155 ±2°C
Step 4 : 10 to 15 minutes at room temperature
Resistance change after 1000 hours (1.5 hours "on", 0.5 hour
"off" ) at RCWV in a humidity chamber controlled at 40°C
±3°C and 90 to 95% relative humidity.
Permanent resistance change after 1000 hours
operating at RCWV, with duty cycle 1.5 hours "on", 0.5
hour"off" at 70°C ±2°C ambient.
Temporary resistance change after 1000 hours exposure in a
humidity test chamber controlled at 40 ±2°C and 90 to 95%
relative humidity.
Test temperature of solder
Dipping time in solder
: Resistance value at room temperature (t1)
: Resistance value at room temperature plus
100°C (t2).
Test Methods (JIS C 5202)
: Room temperature(t1),
Room temperature+100°C(t2)
6
(PPM/°C).
: 245 ±3°C
: 2 to 3 seconds.
03/05/08 V1.1