MCHV06W8J0104T5E MULTICOMP, MCHV06W8J0104T5E Datasheet - Page 3

RESISTOR, HV, 100KOHM, 125mW, 5%

MCHV06W8J0104T5E

Manufacturer Part Number
MCHV06W8J0104T5E
Description
RESISTOR, HV, 100KOHM, 125mW, 5%
Manufacturer
MULTICOMP
Series
HV06r
Datasheet

Specifications of MCHV06W8J0104T5E

Resistance
100kohm
Resistance Tolerance
± 5%
Power Rating
125mW
Voltage Rating
400V
Resistor Element Material
Thick Film
Temperature Coefficient
± 200ppm/°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Performance specification
Temperature coefficient
Short time overload
Humidity (steady sta t e )
Terminal bending
Temperature cycling
Load life in humidity
Solderability
Load life
HV06 Series High Voltage Resistors
Characteristics
± 200 PPM/°C
∆R ≤±(2.0%+0.1Ω) maximum
∆R ≤±(3.0%+0.1Ω) maximum
± (1.0% + 0.05Ω) maximum
5%:∆R ≤±(1.0%+0.05Ω)
maximum
∆R ≤±(3.0%+0.1Ω) maximum
95 % coverage minimum
Go up tin rate bigger than half of
end pole.
∆R ≤±(3.0%+0.1Ω) maximum
Limits
Page 3
Reflow:
Natural resistance change per temperature degree centigrade
R2-R1/ R1 (t2-t1) x 10
R1
R2
Test pattern
Permanent resistance change after the application of a
potential of 2.5 times RCWV for 5 seconds.
Temporary resistance change after 1000 hours exposure
in a humidity test chamber controlled at 40±2°C and
90 to 95% relative humidity
Resistance change after continuous 5 cycles for duty cycles
specified below
Step 1 : 30 minutes at -55±3°C
Step 2 : 10 to 15 minutes at room temperature
Step 3 : 30 minutes at 155±2°C
Step 4 : 10 to 15 minutes at room temperature
Twist of Test Board
Resistance change after 1000 hours
(1.5 hours "on", 0.5 hour "off" ) at RCWV
in a humidity chamber controlled at 40°C ±2°C and
90 to 95 % relative humidity
Permanent resistance change after 1000 hours operating at
RCWV with duty cycle of (1.5 hours "on", 0.5 hour "off") at
70°C ±2°C ambient.
Test temperature of solder
Dipping time in solder
: Resistance value at room temperature (t1)
: Resistance value at room temperature plus
100°C (t2).
Test Methods (JIS C 5201-1)
: Room temperature(t1),
Room temperature +100°C(t2)
6
(PPM/°C).
: Y/X = 3/90 mm for 60 seconds
: 245 ±3°C
: 2 to 3 seconds
16/04/08 V1.1

Related parts for MCHV06W8J0104T5E