1217527-2 Tyco Electronics, 1217527-2 Datasheet - Page 9

no-image

1217527-2

Manufacturer Part Number
1217527-2
Description
CONN RCPT FLAG 14-18AWG .187 TIN
Manufacturer
Tyco Electronics
Series
Faston™r
Datasheet

Specifications of 1217527-2

Terminal Type
Standard
Gender
Female
Tab Width
0.187" (4.75mm)
Tab Thickness
0.032" (0.81mm)
Tab Length
0.250" (6.35mm)
Termination
Crimp, Flag
Wire Gauge
14-18 AWG
Insulation
Non-Insulated
Mounting Type
Free Hanging (In-Line), Right Angle
Contact Material
Phosphor Bronze
Contact Finish
Tin
Insulation Diameter
0.075" ~ 0.155" (1.90mm ~ 3.94mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Color
-
Length - Overall
-
Test Specifications
Temperature Rise and
Millivolt Drop
Test Parameters for FASTON Terminals (Based on UL-310 Temperature Rise and Current Requirements)
Note: This information applies only to
UL listed
Component Recognition
from the electrical or other requirements
defined in the UL-310 safety standard.
This table can be used as a guide for selecting a characteristic such as Contact Size, Wire Size, or Current (either Continuous or Intermittent Operating
Current) when the other two are known. This table also identifies the possible receptacle sizes available for a given wire size. The continuous current column
highlights the maximum current that should be applied to a given receptacle and wire combination to meet a 30°C maximum temperature rise. Intermittent
Current can be defined as a one hour cycle consisting of 45 minutes on and 15 minutes off. The temperature rise of the connector using the intermittent current
on the corresponding wire size will be less than 85° C. The wire used in the testing to meet these electrical requirements is tin plated copper with stranding as
indicated above in parentheses for terminals intended for internal wiring connections.
Tensile Strength
(forces for crimp pull-out)
Catalog 82004
Revised 10-07
www.tycoelectronics.com
R
Series
terminals. A part with a
250
Contact Size
Series
R
205
status deviates
are metric equivalents.
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
Series
187
FASTON Terminals (Insulated and Uninsulated)
Test Specifications
The following information
and related charts are
taken from the qualification
requirements as defined in
UL-310, the Safety Standard
The temperature rise and
millivolt drop characteristics
are the lowest in the indus-
try. They comply with safety
requirements and exhibit
extreme stability during
extended time tests.
Maximum tensile strength
of the wire to terminal con-
nection does not insure reli-
able electrical performance.
An acceptable compromise
between maximum tensile
strength and electrical
stability is recommended.
Forces for Crimp Pull-out Test (UL-310 Specification)
The forces shown for the crimp pull out test represent the minimum force required to separate the wire from the
crimped terminal in an axis parallel to the wire exit direction from the contact. This force does not include the holding
force of the insulation crimp (if applicable).
AWG
22
20
18
16
14
12
10
Series
110
Wire Size
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
(mm
0.32
0.52
0.82
1.3
2.1
3.3
5.3
Wire Size (Strand Count)
2
)
(Continued)
10 (105)
12 (65)
14 (41)
16 (26)
18 (16)
20 (10)
22 (7)
16 (26)
18 (16)
20 (10)
22 (7)
for Electrical Quick-Connect
Terminals. Throughout this
catalog, when a reference
is made to a part being UL
Listed, that part has been
When using FASTON
terminals, the allowable
connection temperatures
can be adjusted, based on
the application, by consid-
ering actual current(s) and
related temperature rise,
Normally the tensile
strength is much greater
than the force required to
disconnect the tab from the
receptacle; therefore, no
difficulties or hazards are
encountered.
pounds
13
20
30
50
70
80
8
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
Minimum Force
Continuous Current
24
20
15
10
7
4
3
5
4
3
2
133
223
311
356
36
58
89
N
qualified to the standards
shown in these charts.
time at this temperature,
humidity, corrosion
environment, vibration,
base metal, plating (if any),
and other environmental
considerations.
Intermittent Current
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080-208
48
40
30
20
14
10
8
6
8
6
4
9

Related parts for 1217527-2