LK204-25-R Matrix Orbital, LK204-25-R Datasheet - Page 15

LCD Character Display Modules Black Background Red Text

LK204-25-R

Manufacturer Part Number
LK204-25-R
Description
LCD Character Display Modules Black Background Red Text
Manufacturer
Matrix Orbital
Series
LK204-25r
Datasheet

Specifications of LK204-25-R

Character Count X Line
20 x 4
Module Size (w X H X T)
98 mm x 60 mm x 27.5 mm
Fluid Type
STN
Background Color
Black
Voltage Rating
5 V
Operating Temperature Range
0 C to + 50 C
Backlight Type
LED Red
Display Mode
Transmissive
Display Type
TN - Twisted Nematic
Number Of Digits/alpha
80
Outline L X W X H
98.00mm x 60.00mm x 27.50mm
Viewing Area
76.00mm L x 25.20mm W
Backlight
-
Display Format
20 x 4
Character Size
4.75mm H x 2.95mm W
Character Format
5 x 7 Dots
Voltage - Supply
5.0V
Dot Size
-
Interface
I²C, RS232, TTL
Operating Temperature
0°C ~ 50°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power Through DB9 Jumper
In order to provide power through pin 9 of the DB-9 Connector you must connect the Power Through
DB-9 Jumper labelled R17, as illustrated below. This connection can be made using a zero ohm resistor,
recommended size 0603, or a solder bridge. The LVK204-25 allows all voltage models to use the power
through DB-9 option, see the electrical specifications in Table 40 for voltage requirements.
Power Through DB9 Jumper
Protocol Select Jumpers
The Protocol Select Jumpers provide the means necessary to toggle the standard LVK204-25 model
between RS-232, TTL and I²C protocols. As a default, the jumpers are set to RS-232 mode with solder
jumps on the 232 jumpers. In order to place the display module in I²C mode you must first remove the
2
solder jumps from the 232 jumpers and then place them on the I
C jumpers. The display will now be in
I²C mode and have a default slave address of 80, unless it has been changed. Similarly, in order to
change the display to TTL mode, simply remove the zero ohm resistors from the 232 or I²C jumpers and
solder them to the TTL jumpers. Protocol changes are only supported on the standard unit.
15