NHD-24064WG-ATFH-VZ#000-CB Newhaven Display, NHD-24064WG-ATFH-VZ#000-CB Datasheet - Page 34

LCD Graphic Display Modules & Accessories 240 x 64 FSTN (+) 180.0 x 65.0

NHD-24064WG-ATFH-VZ#000-CB

Manufacturer Part Number
NHD-24064WG-ATFH-VZ#000-CB
Description
LCD Graphic Display Modules & Accessories 240 x 64 FSTN (+) 180.0 x 65.0
Manufacturer
Newhaven Display

Specifications of NHD-24064WG-ATFH-VZ#000-CB

Pixel Density
240 x 64
Fluid Type
FSTN Positive
Module Size (w X H X T)
240 mm x 180 mm x 65 mm
Backlighting
LED White
Operating Temperature Range
- 20 C to + 70 C
Product
Graphic LCD Module
Display Mode
Transflective
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
12.Reliability
Newhaven Display International, LLC
Content of Reliability Test
High Temperature
storage
Low Temperature
storage
High Temperature
Operation
Low Temperature
Operation
High Temperature/
Humidity Storage
High Temperature/
Humidity Operation
Temperature Cycle
Vibration test
Shock test
Atmospheric
pressure test
Static electricity
test
Test Item
Endurance test applying the high storage
temperature for a long time.
Endurance test applying the high storage
temperature for a long time.
Endurance test applying the electric stress
(Voltage & Current) and the thermal stress to
the element for a long time.
Endurance test applying the electric stress
under low temperature for a long time.
Endurance test applying the high temperature
and high humidity storage for a long time.
Endurance test applying the electric stress
(Voltage & Current) and temperature /
humidity stress to the element for a long time.
Endurance test applying the low and high
temperature cycle.
Endurance test applying the vibration during
transportation and using.
Constructional and mechanical endurance test
applying the shock during transportation.
Endurance test applying the atmospheric
pressure during transportation by air.
Endurance test applying the electric stress to
the terminal.
-10
30min
Note: Max operating and storage altitude: 10,000 ft.
1 cycle
Content of Test
5min
25
Environmental Test
30min
60
60
200hrs
-10
200hrs
50
200hrs
0
200hrs
60 ,90%RH
96hrs
50 ,90%RH
96hrs
-10 /60
10 cycles
10~22Hz 1.5mmp-p
22~500Hz 1.5G
Total 0.5hrs
50G Half sign
wave 11 msedc
3 times of each
direction
115mbar
40hrs
VS=800V,RS=1.5k
CS=100pF
1 time
Test Condition
NHD-24064WG-ATFH-VZ#000-CB
Applicable
Mechanical Test
Standard
——
——
——
——
——
——
——
——
——
——
——
34