E3JU-R5M4T-3 Omron, E3JU-R5M4T-3 Datasheet - Page 8

Photoelectric Sensors - Industrial Polrzd refl 5M timer 300V cable relay out

E3JU-R5M4T-3

Manufacturer Part Number
E3JU-R5M4T-3
Description
Photoelectric Sensors - Industrial Polrzd refl 5M timer 300V cable relay out
Manufacturer
Omron
Series
E3JUr
Datasheet

Specifications of E3JU-R5M4T-3

Features
Sensitivity adjustment
Sensing Method
Polarized Retroreflective
Sensing Distance
5 m
Light Source
Red LED
Amplifier Type
Self Contained
Connection
Prewired Cable
Output Configuration
Relay
Output Current
3A
Sensor Output
Relay
Sensor Input
Optical
Sensing Range Max
5m
Switch Terminals
Cable
Sensing Mode
Polarized Retroreflective
Rohs Compliant
Yes
Sensing Object
Mirror
Sensing Light
Red
Mounting Type
Bracket Mount
Current - Supply
-
Voltage - Supply
12 V ~ 240 V
Package / Case
Module, Pre-Wired
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E3JU
J SENSITIVITY ADJUSTMENT (DIFFUSE REFLECTIVE SENSORS)
8
Steps
Function
Sensing
condition
Sensitivity
adjuster
Indicators
Procedure
Step 1
Determine position A
Photoelectric sensor
Place target at the desired sensing
distance. Set sensitivity adjuster to the
minimum scale position, and gradually
increase sensitivity by turning the
sensitivity adjuster clockwise until the
Light Incident indicator (red LED)
turns ON. Position A designates the
point at which the LED has turned ON.
Min
A
ON
LIGHT
Indicator (red)
Target
Max
Incident
Background
Step 2
Determine position B
Remove the target. Starting from the
maximum scale position, gradually
decrease sensitivity by turning the
sensitivity adjuster counterclockwise
until the Light Incident indicator (red
LED) turns OFF. Position B
designates the point at which the LED
has turned OFF.
Photoelectric sensor
Min
OFF
Target
LIGHT
Indicator (red)
B
Max
Incident
Background
Step 3
Adjust to optimum setting
Set the sensitivity indicator to the
position between Positions A and B (in
some cases, Positions A and B are
opposite of the above example). To
insure stable sensor operation, the
green stability indicator should be fully
“on” in both the sensing and
non-sensing conditions.
Photoelectric sensor
Min
A
OFF
LIGHT Incident
Indicator (red)
Target
B
Max
Background
E3JU