Datasheets

Specifications of E3T-SL24

Output Current
50mA
Sensor Output
PNP
Supply Voltage Range Dc
12V To 24V
Sensor Housing
Rectangular
Sensing Range Min
5mm
Sensor Input
Optical
Supply Voltage Max
24VDC
Sensing Range Max
30mm
Sensing Distance
0.197" ~ 1.181" (5mm ~ 30mm) ADJ
Sensing Method
Reflective, Convergent
Sensing Object
White Paper
Output Configuration
PNP - Open Collector/Dark-ON
Sensing Light
Red
Mounting Type
Bracket Mount
Current - Supply
20mA
Voltage - Supply
12 V ~ 24 V
Package / Case
Module, Pre-Wired
Features
High Precision Alignment
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
J SLITS/APERTURES (ORDER SEPARATELY)
Adjustable Aperture
E39-E10 (Use with E3T-ST1j)
With the Adjustable Aperture
Unit in Place
E39-R37 Reflector
E39-S63 (Use with E3T-ST1j)
E3T
Material:
0.2-mm-thick stainless steel
(301 Stainless)
(0.29)
7.4
Optical axis
1.0±0.05 dia.
0.5±0.05 dia.
(0.29)
7.4
(0.50)
12.6
2 dia.
Two, 2.2 dia.
Two 3.1 dia
(0.54)
13.7
(0.59)
15.1
301 Stainless steel
Shown with Sensor
Notch
(0.74)
18.7
Note: Align the notch direction of
(0.29)
7.4
the slit when installing on
the Emitter and Receiver.
Note: A reflector and a stainless steel mounting
(0.38)
Use of E39-E10 Adjustable Aperture
(Example Dark-ON: E3T-ST12/ST14)
9.7
For Dark-ON:
1. Mount the unit on the receiver.
2. Set the adjuster of the Unit to Max (factory setting is
3. Adjust the optical axis (align) and tighten mounting
4. Place a target between emitter and receiver and
5. Remove the target and confirm that the operation
Note: For Light-ON, adjustment is similar, except that
(At Min.)
at Max).
hardware.
gradually turn the adjuster counterclockwise toward
the Min side. Stop turning the adjuster when the op-
eration indicator and stability indicator (green) turn
ON.
indicator is OFF and the stability indicator (green) is
ON.
plate are supplied together as a set.
indicators would operate in opposite manner as
with Dark-ON.
Stainless steel
mounting plate 0.5
(0.91)
23
(At Center)
E39-S64 (Use with E3T-FT1j)
(0.48)
Reflector
0.6 (with adhesive)
12.3
0.5 dia.
1 dia.
(At Max.)
(0.16)
4.1
Indicator
Adjuster
E3T
11