B84143A120R21 EPCOS Inc, B84143A120R21 Datasheet

Power Line Filters 120A 760/440V 3-LINE

B84143A120R21

Manufacturer Part Number
B84143A120R21
Description
Power Line Filters 120A 760/440V 3-LINE
Manufacturer
EPCOS Inc
Datasheets

Specifications of B84143A120R21

Operating Frequency
50 to 60Hz
Current Rating (max)
120A
Voltage Rating Max
690VAC
Termination
Screw
Mounting Style
Flange
Product Length (mm)
348mm
Product Depth (mm)
171mm
Product Height (mm)
141mm
Voltage Rating
480 VAC / 275 VAC
Current Rating
120 A
Termination Style
Terminal Block
Lead Free Status / RoHS Status
Not Compliant
© EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.
3−line filters
for converters and power electronics
760/440 V, 50/60 Hz, 25A to 180A, 40 °C
Ordering code:
Date:
Version:
B84143A0025...A0180R021
2008−11−26
04

Related parts for B84143A120R21

B84143A120R21 Summary of contents

Page 1

V, 50/60 Hz, 25A to 180A, 40 °C Ordering code: Date: Version: © EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS’ ...

Page 2

Construction S 3 line filter S Metal case Features S High insertion loss S Low leakage current S Easy to install S Degree of protection Space saving design S Design ...

Page 3

Typical circuit diagram LINE Technical data and measuring conditions Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Rated ...

Page 4

Characteristics and ordering codes Terminal R leak cross section < < < < 12 120 ...

Page 5

Dimensional drawings B84143A0025R021; B84143A0050R021 Please read and Cautions and warnings and Important notes at the end of this document. B84143A0025...A0180R021 Page all dimensions in mm B84143−A25_A180−R21−04−7659 ...

Page 6

Dimensional drawings B84143A0080R021 Please read and Cautions and warnings and Important notes at the end of this document. B84143A0025...A0180R021 Page all dimensions in mm B84143−A25_A180−R21−04−7659 ...

Page 7

Dimensional drawings B84143A0120...A0150R021 Please read and Cautions and warnings and Important notes at the end of this document. B84143A0025...A0180R021 Page all dimensions in mm B84143−A25_A180−R21−04−7659 ...

Page 8

Dimensional drawings B84143A0180R021 Please read and Cautions and warnings and Important notes at the end of this document. B84143A0025...A0180R021 Page all dimensions in mm B84143−A25_A180−R21−04−7659 ...

Page 9

Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143A0025R021 100 ...

Page 10

Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143A0150R021 100 ...

Page 11

Caution and warnings S Please note the advices in our data book “EMC Filters” (latest edition); attention should be paid to the chapter “General safety notes” shall be ensured that only ...

Page 12

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical ...

Related keywords