Page 1
... P –> E 2600VDC for 2 sec (FN 351) P –> P 1900VDC for 2 sec (FN 351) P –> E 2750VDC for 2 sec (FN 351H) P –> P 2250VDC for 2 sec (FN 351H) IP20 4x rated current at switch on, 1.5x rated current for 1 minute, once per hour -25° ...
Page 2
... Calculated at rated current, 400VAC (FN 351)/480VAC (FN 351H) and cos phi = 0.8. The exact value depends upon the efficiency of the drive, the motor and the entire application. *** Maximum leakage under normal operating conditions (FN 351 at 400V, FN 351H at 480V). Note: if two phases are interrupted, worst case leakage could reach 6 times higher levels. ...
Page 3
... Components > FN 351 Mechanical data 5 to 16A types 80 and 110A types Dimensions (-H) A 150 180 200 B 105 115 150 120 E 85 115 115 F 90 100 136 G 6.5 6.5 6 19. All dimensions in mm; 1 inch = 25.4mm Tolerances according: ISO 2768 / EN 22768 Filter input/output connector cross sections ...