Specifications of FN 660-1/07

Operating Frequency
0 to 400Hz
Current Rating (max)
1A
Voltage Rating Max
250VAC
Termination
Quick Connect
Mounting Style
Flange
Operating Temp Range
-25C to 100C
Lead Free Status / RoHS Status
Compliant
Technical specifications
Maximum continuous operating voltage:
Operating frequency:
Rated currents:
High potential test voltage:
Temperature range (operation and storage):
Flammability corresponding to:
Design corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
Features and benefits
n
easy and fast chassis mounting.
n
versions without Y-capacitors for medical
applications with necessity for low leakage
currents.
n
conducted attenuation performance, based
on chokes with high saturation resistance
and excellent thermal behavior.
FN 660 two-stage filters are designed for
FN 660 filters are also available as B
All filters provide a high
Two-stage general performance
EMI filter
n
n
n
250VAC, 50/60Hz
dc to 400Hz
1 to 20A @ 40°C max.
P –> E 2000VAC for 2 sec
P –> E 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec
-25°C to +100°C (25/100/21)
UL 94V-2 or better
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
350,000 hours
n
applications requiring good differential
and common-mode attenuation.
n
select the desired connection style.
n
stage filters (FN 610, FN 612 series).
n
FN 660 filters are designed for noisy
Various terminal options allow you to
FN 660 filters are also available as single-
Custom-specific versions on request.
Rated currents from 1 to 20A
High differential and common-mode
attenuation
Optional medical versions (B type)
1-phase filters
FN 660
Approvals
Typical electrical schematic
P
E
N
Typical applications
n
n
n
n
n
n
n
Electrical and electronical equipment
Consumer goods
Power supplies
Building automation
Medical equipment
Office automation equipment
Datacom equipment
Line
Cx
L
Cy
Cx
R
L1
Load
P‘
N‘

Related parts for FN 660-1/07

FN 660-1/07 Summary of contents

Page 1

... FN 660 filters are also available versions without Y-capacitors for medical applications with necessity for low leakage currents. All filters provide a high n conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior. 1-phase filters FN 660 Rated currents from 1 to 20A n High differential and common-mode n attenuation Optional medical versions (B type) n 250VAC, 50/60Hz dc to 400Hz 1 to 20A @ 40°C max. P –> E 2000VAC for 2 sec P – ...

Page 2

... Components > FN 660 Filter selection table Filter Rated current Leakage current* @ 40°C (25°C) @ 230VAC/50Hz [A] FN 660-1-.. 1 (1.15) FN 660-3-.. 3 (3.4) FN 660-6-.. 6 (6.9) FN 660-10-.. 10 (11.5) FN 660-16-.. 16 (18.4) FN 660-20-.. 20 (23) FN 660B-1-.. 1 (1.15) FN 660B-3-.. 3 (3.4) FN 660B-6-.. 6 (6.9) FN 660B-10-.. 10 (11.5) FN 660B-16-.. 16 (18.4) FN 660B-20-.. 20 (23) * Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. ...

Page 3

... Components > FN 660 Mechanical data Connection style -06 types Connection style -07 types GNYE Connection style -03, 16A types Connection style -03, 20A types Connection style -10, 20A types Connection style -06, 10 and 16A types Connection style -07, 10A types Connection style -10, 16A types Connection style -06, 20A types ...

Page 4

... Components > FN 660 Dimensions 46.6 ± 29.3 30.3 D 50.5 64.8 E 44.5 49 10.8 12.3 I 19.3 20.8 J 20.3 27.5 K 5.3 5.3 L 6.3 6.3 M 0.7 0.7 N 6.3 x 0.8 6.3 x 0.8 Q Connection style -03 N Connection style -07 AWG type wire AWG 20 AWG 18 Wire length 140 ...