91066-4 TE Connectivity, 91066-4 Datasheet - Page 2

no-image

91066-4

Manufacturer Part Number
91066-4
Description
Insertion/Extraction Tool
Manufacturer
TE Connectivity
Type
Toolr
Datasheets

Specifications of 91066-4

Tool Body Material
Plastic
Rohs Compliant
NA
Lead Free Status / RoHS Status
RoHS Not Applicable
For Use With
AMP RM & RME ARINC 20 Size Contacts
Lead Free Status / Rohs Status
RoHS Exempt Product
3002
Product Facts
Specifications
Temperature Range —
-85˚F to 257˚F [-65°C to 125°C]
Mating and Unmating Forces —
(Max. after 3 cycles)
Size 1 — 27 pounds [120 N]
Size 2 — 60 pounds [267 N]
Size 3 — 105 pounds [467 N]
Contact Retention against
axial load —
Size 22 — 12 pounds [53 N]
Size 20 — 20 pounds [89 N]
Size 16 — 25 pounds [111 N]
Size 12 — 30 pounds [133 N]
Coaxial — 35 pounds [156 N]
(In testing, exposure to rated loads pro-
duced no contact damage and resulted
in displacement less than .015 [0.38])
Voltage/Current Ratings —
Contact
Size 22
Size 20
Size 16
Size 12
Durability — 500 cycles min. —
mating and unmating (In testing, wired
mated connectors cycled at a rate slower
than 300 cycles per hour, showed no
apparent damage or contact resistance
greater than rated values)
High Temperature Tolerance —
1000 hours min. at 257˚F [125°C]
(Wired, mated connectors)
Salt Spray Tolerance — As specified
by MIL-STD-1344, method 1001,
Condition B
Fluid Imperviousness — MIL-L-
23699; MIL-H-5606: 1:3 mix isopropyl
alcohol and mineral spirits (Test immer-
sions of mated connectors in these flu-
ids caused no evident deterioration)
Vibration and Shock Tolerance —
Per MIL-STD-1344, methods 2004-1
and 2005-1 (Testing to these conditions,
including vibration for 8 hours in each of
3 mutually perpendicular axes, caused
no visible cracking, breaking or loosen-
ing of parts, and no discontinuities
exceeding 1 microsecond)
Humidity Tolerance — Insulation
resistance 1 megohm min., 1-2 hours
after exposure to humidity per MIL-STD-
1344, Method 1002-1, Type II; 5000
megohm min. after 24 hours at 77˚F
[25°C].
Catalog 1308940
Revised 5-03
www.tycoelectronics.com
Designed to meet relevant
ARINC 600 Connector
specifications
Available in three sizes
Low mating-force contacts —
suitable for ARINC 404
Connectors
Full range of contact inserts
AWG
22
20
16
12
Max. Current (A)
13.0
23.0
5.0
7.5
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
ARINC 600 Connectors
Introduction
Dielectric Withstanding Voltage —
(Min.) 1500 VAC, RMS 60 Hz at sea
level; 500 VAC, RMS 60 Hz at 50,000 ft.
[15240 M] (Testing at rated voltages for
60 seconds produced no flash over and
1 mA leakage, max.)
Insulation Resistance — 1000
megohms min. (Test conducted on
unmated connector after 30 min. expo-
sure to 248˚F–257˚F [120°C–125°C])
Contact Resistance — Mated pairs
tested per MIL-STD-1344, Method
3004-1
Technical Document — ARINC 600
Product Specification 108-10050
ARINC 600 Connectors are
used in virtually all airframes
and today's state-of-the-art
avionics equipment. From
collision avoidance (TCAS,
TAWS) to in-flight entertain-
ment/networking, new avion-
ics equipment demands
higher data transmission
rates. Whether it's Fibre
Channel, or 100-Base-T or
100-Base-FX Ethernet and
beyond, Tyco Electronics
has the insert configurations
and copper and fiber hard-
ware (Quadrax contacts, RF,
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
and Mini-Expanded Beam
Fiber Optics) to meet the
need. Standard industry
configurations are available.
For designs that require
custom configurations,
Tyco Electronics will work
with you to provide the
connector solution required.
ARINC 600 Connectors
represent a new generation
of standardized rack and
panel connectors for aircraft
applications. Compared to
the preceding ARINC 404
standard, the new avionics
connectors feature signifi-
cantly reduced mating
forces; increased numbers
of contacts in housings
proportioned to thinner
black-box shapes; and
floating, front-release keying.
ARINC 600 Connectors cap-
italize on the new design by
adding unique features while
maintaining intermateability.
For instance, AMP contact
inserts are field replaceable
and manufactured to precise
tolerances.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
AMP contacts for ARINC 600
Connectors are applied with
standard crimping tools—the
same ones used for ARINC
404 contacts. Automatic
crimping equipment is avail-
able for higher productivity
and lower applied costs.
The benefits of ARINC 600
reduced engagement force
contacts (for example: size
22 contacts averaging 1.5
ounces [0.42 N]) can be
realized in ARINC 404 con-
nectors through the use of
the interchangeable ARINC
600 contacts. ARINC 600
coaxial contacts also are
crimp applied for reliable,
solder-free installation.
It is easy to specify ARINC
600 Connectors by descrip-
tive part numbers. An exam-
ple of a descriptive part
number is shown on page
3003, with an explanation of
each component of the part
number and page references
for complete information.
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967

Related parts for 91066-4