11 QLA-01-2-9 / 122 NH Huber + Suhner AG, 11 QLA-01-2-9 / 122 NH Datasheet - Page 2

no-image

11 QLA-01-2-9 / 122 NH

Manufacturer Part Number
11 QLA-01-2-9 / 122 NH
Description
Manufacturer
Huber + Suhner AG
Datasheet

Specifications of 11 QLA-01-2-9 / 122 NH

Gender
PL
Body Style
Straight
Terminate To
Coaxial Cable
Mounting Style
Cable
Termination
Crimp
Operating Temp Range
-55C to 105C
Body Plating
Nickel
Contact Plating
Gold Over Nickel
Contact Material
Brass
Body Material
Brass
Product Length (mm)
27.1mm
Lead Free Status / RoHS Status
Supplier Unconfirmed
TECHNICAL DATA
1) Value considers maximum load of the cables without irreversible variations of specifications.
158
ELECTRICAL DATA
Impedance
Frequency range
Dielectric withstanding voltage
(at sea level)
Working voltage (at sea level)
- unmated
- mated
Insulation resistance
Contact resistance
- centre contact
- outer contact
VSWR (typical value for mated
connector pair) 11 QLA - 21 QLA
RF-leakage (measured at 500 MHz)
MECHANICAL DATA
Engagement force
Disengagement force
Contact captivation
Cable retention force
Durability (matings)
ENVIRONMENTAL DATA
Temperature range
Thermal shock
Moisture resistance
Corrosion
Vibration
Shock
1)
REQUIREMENTS
50
DC ... 1.4 GHz
1.5 kV, 50 Hz
DC ... 300 MHz = 1.15
300 MHz - 1.4 GHz = 1.20
REQUIREMENTS
typ. 2 N / .45 lbs
typ. 5 N / 1.1 lbs
see pages 28 – 34
TEST CONDITIONS
– 55 C ... + 150 C / – 67 F ... + 302 F
MIL-STD-202, Method 107, Condition B
MIL-STD-202, Method 106
Saltspray test acc. to MIL-STD-202, Method 101, Condition B
MIL-STD-202, Method 204, Condition D
MIL-STD-202, Method 213, Condition I
300 V rms, 50 Hz
500 V rms, 50 Hz
10
4 m
2 m
80 dB
20 N / 4.5 lbs
10 000
HUBER+SUHNER
6
M
QLA 00

Related parts for 11 QLA-01-2-9 / 122 NH