F2410 POWER ONE, F2410 Datasheet - Page 27
![](/photos/30/87/308722/filters_datasheet_sml.jpg)
F2410
Manufacturer Part Number
F2410
Description
Manufacturer
POWER ONE
Datasheet
1.F2410.pdf
(41 pages)
Specifications of F2410
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
85C
Rad Hardened
No
Lead Free Status / RoHS Status
Not Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
F2410-G
Manufacturer:
PowerOne
Quantity:
468
Company:
Part Number:
F2410-G
Manufacturer:
OMRON
Quantity:
101
F & FC Series DC-DC Converter Input Filters
FC Series, 0-100V, 5/10/20 Amps, TH Mount
EMI Measurement Methodology
There are two methods of measurement for input conducted EMI: voltage measurements and current measurements. The
voltage data presented uses a 50S LISN (Line Impedance Stabilization Network) and measures the input voltage spectrum
from each input line of the converter to ground, using FCC and CISPR measurement techniques. The current data uses a
10 microfarad capacitor from each input line to ground, and measures the current in both lines simultaneously using the
measurement technique defined in section 3.4.5, part B3 of the Bellcore document GR-1089-CORE. In each case, there was
no external input filter. There was only an appropriate value capacitor across the input lines. The case of the unit under test
was grounded to the reference ground plane, as was the output common of the unit. All spectra presented were taken with
production grade modules, operating from 48 VDC at the full-rated output load current.
Figure 15. Input Conducted EMI Voltage Test Circuit
MCD10059 Rev. 1.1, 21-Jan-10
Page 27 of 41
www.power-one.com