A4934GLPTR-T Allegro Microsystems Inc, A4934GLPTR-T Datasheet - Page 5

IC BLDC DVR 3PHASE 16-ETSSOP

A4934GLPTR-T

Manufacturer Part Number
A4934GLPTR-T
Description
IC BLDC DVR 3PHASE 16-ETSSOP
Manufacturer
Allegro Microsystems Inc
Datasheet

Specifications of A4934GLPTR-T

Applications
Fan Motor Driver, 3-Phase
Number Of Outputs
1
Current - Output
500mA
Voltage - Supply
8 V ~ 16 V
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP (0.173", 4.40mm Width) Exposed pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / RoHS Status
Supplier Unconfirmed, Lead free / RoHS Compliant
Other names
620-1382-2
A4934
the commutation delay period, a CDCOM is asserted, starting
the Blank timer. The Blank signal disables the BEMF detector so
the comparator is not active during the commutation transients.
The next zero crossing, detected on the tri-stated output, causes
FCOM to go high. This triggers the Commutation Delay timer
and the sequence repeats.
Startup
At startup, commutations are provided by an onboard oscillator.
These commutations are part of the startup scheme, to step the
motor to generate BEMF until legitimate BEMF zero crossings
are detected and normal BEMF sensing commutation is achieved.
Until an appropriate number of FCOM pulses are achieved (96),
100% PWM will be applied to the motor windings.
Standby Mode
Driving PWM low for 500 μs causes the IC to enter a low power
standby mode.
Lock Detect
Valid FCOM signals must be detected to ensure the motor is not
stalled. If a valid FG is not detected for 2 s, the outputs will be
disabled for 5 s before an auto-restart is attempted.
FG Output
The FG output provides fan speed information to the system.
FG is an open drain output.
PWM Input
The duty cycle applied to the PWM pin is translated directly
to an average duty cycle applied across the motor windings
to control speed.
• For voltage controlled applications, where V
• PWM also can be used as a control input to start and stop the
speed, PWM can be left open circuit. PWM is internally pulled-
up to logic high level.
motor.
BB
controls the
Three-Phase Sensorless Fan Driver
• For PWM applications, input frequencies in the range
SLEW Input
Controls the level of soft switching:
FC Input
This is the logic input to set force commutation time at startup, by
connection as follows:
Overcurrent Protection
If needed, a sense resistor can be installed to limit current. (See
Applications Information section for more details.) The current
limit trip point would be set by:
When the trip point is reached, if the threshold voltage, V
exceeded, the drivers will be disabled for 25 μs.
15 to 30 kHz are applied directly to the motor windings. If the
PWM duty cycle is very small, then the IC will apply a mini-
mum pulse width of typically 6 μs. This minimum pulse width
effects the minimum speed. As a result of having a minimum
pulse width, the IC can startup and operate down to very short
duty cycles.
FC Pin Connection
SLEW Pin Connection
Open
GND
VBB
Open
GND
I
OCL
115 Northeast Cutoff
1.508.853.5000; www.allegromicro.com
Allegro MicroSystems, Inc.
Worcester, Massachusetts 01615-0036 U.S.A.
= 200 mV / R
Startup Commutation Time
Soft Switch Status
S
More
Less
.
(ms)
100
200
50
OCL
, is
5

Related parts for A4934GLPTR-T