0
UM0979
4.2.6
Table 10.
4.3
*setdbXXXVY
Command
*pwAADD
*echoon
*echooff
*debug
*listdev
*single
*prAA
*start
*stop
*Zon
*Zoff
*dev
*ver
*list
Digital output pressure sensor: supported commands
Table 10
boards:
Digital output pressure sensor: supported commands list
Quick start
This section shows the basic sequence of commands, based on the LIS3DH accelerometer,
to start a data communication session and to retrieve the X, Y, and Z acceleration data from
the demonstration kit:
1.
2.
3.
4.
5.
STEVAL-MKI112V1 (LPS001WP)
Connect the eMotion to the USB port
Start “Microsoft
Inside the “HyperTerminal” window, enter the command *setdb105v1 (supposing the
LIS3DH adapter board is used, for other adapters see the relevant datasheets to check
the register configuration), enter the command *Zoff to enable the control of the device
by the STM32F102RB microcontroller, and *w2047 to switch on the LIS3DH and to set
the data rate to 50 Hz
Send the *debug command to get the X, Y, and Z data measured by the sensor
Send *stop to end the continuous acquisition and visualization.
below lists the commands supported by the following devices/demonstration
It gets a single X, Y, and Z data acquisition
Selects firmware according to the adapter
Returns the output data in readable text
Deactivates the write verbose mode
Prints the list of devices supported
Starts continuous data acquisition
Activates the write verbose mode
Prints the list of MKIs supported
Pressure sensor register write
Pressure sensor register read
©
Stops data acquisition
HyperTerminal” and configure it as described in
Exits from 3-state
Firmware version
Forces 3-state
Device name
Description
connected
format
Doc ID 17768 Rev 1
e.g.: PRAAhDDh
Returned value
e.g.: MKI105V1
e.g.: RAAhDDh
(see
(see
e.g.: LIS3DH
(see
e.g.: LIS3DH
e.g.: V1.0
Supported commands
Table
Table
Table
Section 4.1
4)
5)
5)
25/32