G2R-1-E-AC120 Omron, G2R-1-E-AC120 Datasheet - Page 2

RELAY PWR SPDT 16A 120VAC PCB

G2R-1-E-AC120

Manufacturer Part Number
G2R-1-E-AC120
Description
RELAY PWR SPDT 16A 120VAC PCB
Manufacturer
Omron
Series
G2Rr

Specifications of G2R-1-E-AC120

Contact Form
SPDT (1 Form C)
Contact Rating (current)
16A
Switching Voltage
380VAC, 125VDC - Max
Turn On Voltage (max)
96 VAC
Turn Off Voltage (min)
36 VAC
Relay Type
General Purpose
Coil Type
Non Latching
Coil Current
7.5mA
Coil Voltage
120VAC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
16A @ 250VAC
Control On Voltage (max)
96 VAC
Control Off Voltage (min)
36 VAC
Coil Voltage Vac Nom
120V
Contact Current Max
16A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
6500ohm
Contact Configuration
SPDT
Current, Rating
16 A
Function
Power
Number Of Pins
8
Power, Rating
4000⁄480 VA⁄W
Standards
UL, CSA, VDE, CE
Termination
Through Hole
Voltage, Control
120 VAC
Voltage, Rating
380 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G2R-1-E-AC120
G2R1EAC120
Z3121

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G2R-1-E-AC120
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Construction
■ SEALING
Unsealed
Relays of this type are intended for manual soldering. No measures
are taken against penetration of flux and cleaning solvent into the
relay. This type of relay cannot be immersion-cleaned.
Semi-Sealed
Special design construction prevents flux from penetrating into the
relay housing, for example, due to capillary action up the terminals
when the relay is soldered onto a PCB. This type of relay also cannot
be immersion-cleaned.
2
Construction
Features
Automatic flux
application
Automatic soldering
Automatic cleaning
Manual soldering
Penetration of dust
Penetration of corrosive
gas
Construction
Features
Automatic flux
application
Automatic soldering
Automatic cleaning
Manual soldering
Penetration of dust
Penetration of corrosive
gas
Classification
Classification
Electromechanical Relays
Terminals are separated
from PCB surface when re-
lay is mounted.
Poor
Poor
Poor
Good
Fair
Poor
Terminals, base, and case are sealed.
Good
Good
Good
Good
Good
Fair
Terminals separated
from PCB
Press-fit terminals
Technical Information
Fully Sealed
Unsealed
Contacts are positioned
away from base.
Poor
Poor
Poor
Good
Resin seal
Contacts located at
upper part of relay case
Fully Sealed
Fully sealing prevents not only flux, but also cleaning solvent from
penetrating into the relay housing. Therefore, this type of relay can
be immersion-cleaned. Relays are each tested before being shipped.
The relay is immersed in fluorocarbon solution for 1 minute, at a tem-
perature of 70°C +5°C/-0°C, to see if gases escape from the relay.
The following figure illustrates the test conditions.
Terminals are pressed into
base.
Good
Good
Poor
Good
Fair
Poor
Terminal and base, as well as the base and casing, are
sealed.
Good
Good
Good
Good
Good
Fair
Terminals
separated
from PCB
Press-fit terminals
50 mm
Fluorocarbon
solution
Resin seal
Relay
Resin seal
Surface Mounting
Semi-Sealed
Terminals are inserted into
base 0.3 mm min. thick.
Good
Good
Poor
Good
Terminals
separated
from PCB
Ex.) 70 °C
Glue pad
Inserted terminals
0.3 mm
min. base
thickness

Related parts for G2R-1-E-AC120