G4A-1A-E DC5 Omron, G4A-1A-E DC5 Datasheet - Page 2

RELAY POWER SPST-NO 5VDC PCB

G4A-1A-E DC5

Manufacturer Part Number
G4A-1A-E DC5
Description
RELAY POWER SPST-NO 5VDC PCB
Manufacturer
Omron
Series
G4Ar

Specifications of G4A-1A-E DC5

Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
20A
Switching Voltage
250VAC - Max
Turn On Voltage (max)
3.5 VDC
Turn Off Voltage (min)
0.5 VDC
Relay Type
General Purpose
Coil Type
Non Latching
Coil Current
180mA
Coil Voltage
5VDC
Mounting Type
Through Hole
Termination Style
PC Pin, .250" Quick Connect
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
20A @ 250VAC
Control On Voltage (max)
3.5 VDC
Control Off Voltage (min)
0.5 VDC
Coil Voltage Vdc Nom
5V
Contact Current Max
20A
Contact Voltage Ac Nom
250V
Coil Resistance
27.8ohm
Contact Configuration
SPST-NO
Current, Rating
20 A
Function
Power
Number Of Pins
4
Power, Rating
5000 VA
Standards
UL, CSA, RoHS, VDE
Termination
Through Hole
Voltage, Control
5 VDC
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G4A-1A-EDC5
G4A-1A-EDC5
G4A1AEDC5
Z3103
Note: P level: λ 60 = 0.1 x 10
with Motor Load
With Overload
With Inverter Load
Note: The data shown above are initial values.
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (ref. value)
250 VAC:
Inrush current: 80 A, 0.3 s (cosø= 0.7)
Break current: 20 A (cosø = 0.9)
250 VAC:
Inrush current: 80 A (cosø= 0.7)
Break current: 80 A (cosfø= 0.7)
100 VAC:
Inrush current: 200 A (0-P)
Break current: 20 A
Contact resistance
Operate time
Release time
Max. Operating Frequency
Insulation resistance
Insulation resistance
Dielectric strength
Shock resistance
Vibration resistance
Endurance
Ambient temperature
Ambient humidity
Weight
PCB Power Relay – G4A
Contact Ratings
Endurance
Characteristics
Load conditions
Load conditions
Load conditions
-6
/operation (with an operating frequency of 120 operations/min).
20 A at 250 VAC
20 A
250 VAC
20 A
5,000 VA
100 mA at 5 VDC
100 mΩ max.
20 ms max.
10 ms max.
Mechanical: 18,000 operations/hr
1000 MΩ max. (at 500 VDC)
100 MΩ max. (at 500 VDC)
4,500 VAC 50/60 Hz for 1 min between coil and contacts
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity
Destruction: 1,000 m/s
Malfunction: 200 m/s
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Mechanical: 2,000,000 operations min. (at 18,000 operations/hr)
Motor load: 100,000 operations min. (ON/OFF: 1.5 s)
Inverter load: 30,000 operations min. (ON: 3 s, OFF: 5 s)
Operating: -20°C to 60°C (with no icing)
Operating: 5% to 85%
Approx. 25 g
ON: 1.5 s
OFF: 1.5 s
ON: 1.5 s
OFF: 99 s
ON: 3 s
OFF: 5 s
2
2
Switching frequency
Switching frequency
Switching frequency
200,000 operations
1,500 operations
30,000 operations
Electrical endurance
Electrical endurance
Electrical endurance
151