Contact Form
4PST-NO-DM (4 Form X)
Contact Rating (current)
40A
Switching Voltage
600VAC - Max
Turn On Voltage (max)
93 VAC
Turn Off Voltage (min)
20 VAC
Relay Type
Contactor
Coil Type
Non Latching
Coil Voltage
120VAC
Mounting Type
Chassis Mount
Termination Style
Box Lug, .250" QC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Other names
7-1611021-4
836
Features
• 4-pole contactors.
• Convenient “universal” mounting plate.
• Optional interlock/auxiliary switches available.
Contact Data @ 25°C
Material: Silver Cadmium Oxide.
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
Arrangements: 4 Form X (4PST-NO-DM).
Maximum Ratings: See Contact Ratings Table.
Coil Data @ 25°C
Insulation Class: UL Class B (130°C).
Duty Cycle: Continuous.
Contact Ratings
Dimensions are shown for
reference purposes only.
Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Coil Data
Amps
Load
Full
25
30
40
Number
Poles
of
3
3
3
Voltage
240/277
240/277
240/277
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Line
480
600
480
600
480
600
6 -15
19.2
24
68
60
14
9
5
Locked
Rotor
Amps
150
125
100
180
150
120
240
200
160
20 - 70
Catalog 1308242
120
148
93
68
60
14
Issued 3-03
9
Resistive
Model 93 - 3100
Definite Purpose Contactor
4-pole, 25-40 FLA
AC Coil
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Environmental Data
Rating
Temperature Range: Storage and Operating: -40°C – +65°C.
Flammability: UL 94-HB housing.
Mechanical Data
Contact Termination:
25, 30 FLA Models
40 FLA Models
Coil Termination: Dual 0.250” (6.35 mm) quick connects, standard.
Arc Cover: Optional on 25-30 FLA models, standard on 40 FLA models.
Weight: 24 oz. (683 g) approximately
Specifications and availability
subject to change.
Amps
35
35
35
40
40
40
50
50
50
Type: #10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque: 25 in.-lbs.
Type: Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size: 14-4 Cu/Al AWG
Tightening Torque: 40 in.-lbs.
File E75492
File EN60947-4-1:1991
IEC 947-4-1
208/240
40 - 140
177
520
9.5
68
60
14
A 0.250” quick connect and a #6-32 screw, optional.
Voltage
110/120
200/208
240/277
110/120
200/208
240/277
110/120
200/208
240/277
480
480
480
Maximum Horsepower
50-185
277
220
750
9.5
58
52
11
Single
Phase
PRODUCTS UNLIMITED
7.5
2
5
2
5
3
-
-
-
-
-
-
series
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
150 - 270
2700
480
384
48
52
11
Three
Phase
9
7.5
10
15
10
10
15
10
10
20
-
-
-

Related parts for 3100-40T10999AT

3100-40T10999AT Summary of contents

Page 1

... Nominal Sealed Nominal DC Resistance - Ohms Dimensions are shown for 836 reference purposes only. Catalog 1308242 Issued 3-03 Model 93 - 3100 Definite Purpose Contactor 4-pole, 25-40 FLA AC Coil File E75492 File EN60947-4-1:1991 IEC 947-4-1 Users should thoroughly review the technical data before selecting a product part number ...

Page 2

... Ordering Information Typical Part No. 1. Series: 3100 = 4-pole, 25-40 FLA contactor 2.Packaging Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration Form X (4PST-NO-DM) 4.Coil Voltage (50/60 Hz.): Q = 24VAC U = 208/240VAC H = 480VAC T = 120VAC V = 277VAC I = 24VAC, molded 5.Contact Ratings (Inductive FLA ...

Related keywords