3100-30J16999CJ TE Connectivity, 3100-30J16999CJ Datasheet - Page 2

RELAY CONTACTOR 50A 120VAC QC

3100-30J16999CJ

Manufacturer Part Number
3100-30J16999CJ
Description
RELAY CONTACTOR 50A 120VAC QC
Manufacturer
TE Connectivity
Series
3100, Products Unlimitedr
Datasheet

Specifications of 3100-30J16999CJ

Contact Form
3PST-NO-DM (3 Form X)
Contact Rating (current)
50A
Switching Voltage
600VAC - Max
Turn On Voltage (max)
93 VAC
Turn Off Voltage (min)
20 VAC
Relay Type
Contactor
Coil Type
Non Latching
Coil Voltage
120VAC
Mounting Type
Chassis Mount
Termination Style
Box Lug, .250" QC
Operating Voltage
600VAC
Switching Power Ac1
10hp
Switching Power Ac3
25hp
Switching Current Ac1
65A
Switching Current Ac3
50A
Load Current Inductive
50A
Load Current Resistive
65A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Other names
4-1611022-6
Auxiliary Switches
Various interlock / auxiliary switches are available for the Model 93 contactor.
Ordering Information
Dimensions are shown for
reference purposes only.
Standard part numbers listed below are more likely to be available from stock.
None at present.
Outline Dimensions
W/ #6-32 SCREW & SADDLE CLAMP
1. Series:
2.Packaging:
3.Pole Configuration:
4.Coil Voltage (50/60 Hz.):
5.Contact Ratings (Inductive):
6.Customer ID Suffix:
7. Option Code:
3100 = 3-pole, 50-60 FLA contactor
Y = Individual Pack
- = Bulk Pack
A-ZZZ = Customer specific information (assigned by factory)
30 = 3 Form X (3PST-NO-DM)
Q = 24VAC
T = 120VAC
16 = 50 FLA
999 = Standard Model
Leave Blank = No customer-specific options
NORMALLY OPEN & CLOSED
Shown with Optional Auxiliary Switch
NORMALLY OPEN
3.563
(90.5)
-303 STYLE
-332 STYLE
-344 STYLE
U = 208/240VAC
V = 277VAC
17 = 60 FLA
000-998 = Factory assigned customer ID
Typical Part No.
H = 480VAC
I = 24VAC, molded
Dimensions are in inches over
(millimeters) unless otherwise
specified.
NORMALLY CLOSED
(78.7)
3.10
-337 & -341 STYLE
(69.9)
(67 .3)
2.75
2.65
-331 STYLE
B
SPDT
J = 120VAC, molded
K = 208/240VAC, molded
A - ZZ = Factory assigned customer-specific options.
3100
(95.25)
3.75
(51.61)
2.032
Catalog 1308242
Issued 3-03
.218 TYP .
(5.537)
Equipped with 0.250” (6.35) Quick Connect Terminals
Equipped with #6-32 Screw Terminals & Saddle Clamps
Footnotes: Ratings of Auxiliary Interlocks / Switches
(1) Contact Rating Single Circuit NO or NC
Specifications and availability
subject to change.
Description
Single unit interlock
configurations listed.
Maximum of two. Must
be same polarity.
See footnote (1) for ratings.
SPDT Circuit
See footnote (2) for ratings.
SPDT Dry Circuit, 0.1 amp max.
Gold Flashed Contacts
Description
Single unit interlock
configurations listed.
Maximum of two. Must
be same polarity. (note 1)
(37 .29)
(56.95)
-
1.468
2.242
and two circuit NO/NC:
Break
Make
Continuous
M = 277VAC, molded
W = 480VAC, molded
30
120V 240V 480V 600V
3.0A
30A
10A
(81.03)
(11.12)
3.19
(6.35)
Factory Modifications
Factory Modifications
.438
.250
(82.55)
3.25
1.5A 0.75A 0.6A
15A
10A
(6.35)
.250
Q
7.5A
10A
Contact Config.
Contact Config.
NO
NO
1
0
1
2
0
2
1
2
1
2
1
0
1
Termination
10A
6A
16
NC
NC
0
1
1
0
2
2
1
2
1
2
0
1
1
(2) Contact Rating SPDT (337):
PRODUCTS UNLIMITED
Lug accepts 14-2
10A, 1/3 HP , 125 or 250 VAC
1/2A, 125 VDC; 1/4A, 250 VDC:
4A 120 VAC on Lamp Load
on 50-60 FLA
Cu/Al AWG
Kit Catalog
34300-303
34300-331
34300-332
34300-303
34300-331
34300-332
34300-337
34300-337
34300-341
34300-340
Kit Catalog
34300-342
34300-343
34300-344
Standard
Number
Number
999
Field Added Kits
Field Added Kits
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
(6.43)
.253
Kits Required
Kits Required
Number of
Number of
1
1
1
2
2
2
1
2
1
1
1
1
1
835

Related parts for 3100-30J16999CJ