TGA2506 TriQuint, TGA2506 Datasheet - Page 11

no-image

TGA2506

Manufacturer Part Number
TGA2506
Description
Wireless Accessories 12-18 GHz Ku Band Driver
Manufacturer
TriQuint
Datasheet

Specifications of TGA2506

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
1014648

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TGA2506
Manufacturer:
AKM
Quantity:
1 500
TriQuint Semiconductor Texas: Phone (972)994-8465 Fax (972)994-8504 Email: Info-mmw@tqs.com Web: www.triquint.com
GaAs MMIC devices are susceptible to damage from Electrostatic Discharge. Proper precautions should
be observed during handling, assembly and test.
Reflow process assembly notes:
Component placement and adhesive attachment assembly notes:
Interconnect process assembly notes:
Use AuSn (80/20) solder with limited exposure to temperatures at or above 300 C (30 seconds max).
An alloy station or conveyor furnace with reducing atmosphere should be used.
No fluxes should be utilized.
Coefficient of thermal expansion matching is critical for long-term reliability.
Devices must be stored in a dry nitrogen atmosphere.
Vacuum pencils and/or vacuum collets are the preferred method of pick up.
Air bridges must be avoided during placement.
The force impact is critical during auto placement.
Organic attachment can be used in low-power applications.
Curing should be done in a convection oven; proper exhaust is a safety concern.
Microwave or radiant curing should not be used because of differential heating.
Coefficient of thermal expansion matching is critical.
Thermosonic ball bonding is the preferred interconnect technique.
Force, time, and ultrasonics are critical parameters.
Aluminum wire should not be used.
Maximum stage temperature is 200 C.
Assembly Process Notes
Product Data Sheet
August 5, 2008
TGA2506
11