... IXYS Dual Diode Modules Absolute Maximum Ratings V RRM V DRM [V] MDD 1200 600-12N1 1400 600-14N1 1600 600-16N1 1800 600-18N1 2000 600-20N1 2200 600-22N1 VOLTAGE RATINGS V Repetitive peak reverse voltage RRM V Non-repetitive peak reverse voltage RSM OTHER RATINGS I Maximum average forward current. T F(AV)M I Maximum average forward current ...
Page 2
... IXYS Characteristics PARAMETER V Maximum peak forward voltage FM V Maximum peak forward voltage FM V Threshold voltage T0 r Slope resistance T I Peak reverse current RRM Q Recovered Charge rr Q Recovered Charge, 50% chord ra I Reverse recovery current RM t Reverse recovery time, 50% chord rr R Thermal resistance, junction to case ...
Page 3
... IXYS Notes on Ratings and Characteristics 1.0 Voltage Grade Table Voltage Grade 2.0 Extension of Voltage Grades This report is applicable to other voltage grades when supply has been agreed by Sales/Production. 3.0 De-rating Factor A blocking voltage de-rating factor of 0.13%/°C is applicable to this device for T 4.0 Snubber Components When selecting snubber components, care must be taken not to use excessively large values of snubber capacitor or excessively small values of snubber resistor ...
Page 4
... IXYS 5.2 Calculating V using ABCD Coefficients F The on-state characteristic I (i) the well established V T0 (ii) a set of constants forming the coefficients of the representative equation for V terms of I given below The constants, derived by curve fitting software, are given below for both hot and cold characteristics ...
Page 5
... IXYS 5.3 D.C. Thermal Impedance Calculation Where the number of terms in the series and Duration of heating pulse in seconds Thermal resistance at time Amplitude of p term τ = Time Constant The coefficients for this device are shown in the tables below: Term 1 r 0.05428 p τ 2.69428 p 6 ...
Page 6
... IXYS Curves Figure 1 - Forward characteristics of Limit device 10000 MD#600-12N1 to 22N1 Issue 2 1000 100 0.6 0.7 0.8 Figure 2 - Transient thermal impedance 0.1 MD#600-12N1 to 22N1 Issue 2 0.01 0.001 0.0001 0.00001 0.00001 0.0001 Data Sheet. MD#600-12N1 to 22N1 Issue 2 Dual Diode Module Types MD#600-12N1 to MD#600-22N1 T = 25° ...
Page 7
... IXYS Figure 3 - Total recovered charge, Q 10000 MD#600-12N1 to 22N1 Issue 2 T =150°C j 1000 1 10 di/dt (A/µs) Figure 5 - Peak reverse recovery current, I 10000 MD#600-12N1 to 22N1 Issue 2 T =150°C j 1000 100 1 10 di/dt (A/µs) Data Sheet. MD#600-12N1 to 22N1 Issue 2 Dual Diode Module Types MD#600-12N1 to MD#600-22N1 ...
Page 8
... IXYS Figure 7 – Forward current vs. Power dissipation 2500 MD#600-12N1 to 22N1 Issue 2 2000 6ø 1500 1000 500 0 0 500 1000 Mean Forward Current (A) (Whole cycle averaged) Figure 9 - Maximum surge Rating 100000 10000 1000 Duration of surge (ms) Data Sheet. MD#600-12N1 to 22N1 Issue 2 Dual Diode Module Types MD#600-12N1 to MD#600-22N1 Figure 8 – ...
Page 9
... IXYS Outline Drawing & Ordering Information ORDERING INFORMATION M D# Fixed Configuration code Type Code DD, DA, DK Order code: MDD600-14N1– MDD configuration, 1400V V IXYS Semiconductor GmbH Edisonstraße 15 D-68623 Lampertheim Tel: +49 6206 503-0 Fax: +49 6206 503-627 E-mail: marcom@ixys.de Westcode Semiconductors Ltd Langley Park Way, Langley Park, Chippenham, Wiltshire, SN15 1GE ...